Description
SICK IMB12-08NDSVU2S DC Two-wire Inductive Sensor
Technical Overview
The SICK IMB12-08NDSVU2S is a standard-body M12 × 1 inductive proximity sensor for non-flush installation. It provides an 8 mm nominal sensing range and 6.48 mm assured range, with material-dependent reduction factors. A normally-open DC two-wire circuit connects through a 2 m PUR cable and switches at 2,000 Hz. Operation requires a 10–30 V DC supply and at least 3 mA load current; the documented off-state current and voltage drop inform input matching. Its V2A stainless steel housing and LCP sensing face provide IP68/IP69K protection and coolant-lubricant resistance. A visual adjustment indicator assists positioning, while two toothed V2A mounting nuts are supplied.
Non-flush M12 inductive sensor with 8 mm nominal range, DC two-wire NO circuit, 2,000 Hz switching and a 2 m PUR cable.
Key Features
- Standard-body M12 × 1; non-flush installation
- 8 mm nominal range; 6.48 mm assured range
- Normally-open DC two-wire circuit; 2,000 Hz switching
- 10–30 V DC; minimum load current 3 mA; continuous current ≤100 mA
- Typical off-state current 0.8 mA; maximum 1.2 mA at maximum supply and 100 °C
- 2 m two-wire PUR cable; 0.34 mm² conductors; 4.5 mm diameter
- Coolant-lubricant resistance and visual adjustment indicator
- V2A stainless steel DIN 1.4305/AISI 303 housing; LCP sensing face
- IP68/IP69K; −40 to +100 °C operating temperature
- Two toothed V2A mounting nuts supplied; 17 mm across flats
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Inductive proximity sensor |
| Housing design | Metric standard body |
| Mounting thread | M12 × 1 |
| Installation | Non-flush |
| Nominal sensing range Sn | 8 mm |
| Assured sensing range Sa | 6.48 mm |
| Output function | Normally open (NO) |
| Electrical wiring | DC two-wire |
| Switching frequency | 2,000 Hz |
| Power supply | 10–30 V DC |
| Ripple | ≤10% |
| Voltage drop | ≤4 V at Ia = 30 mA; ≤4.5 V at maximum Ia |
| Time delay before availability | ≤100 ms |
| Hysteresis | 3–20% |
| Reproducibility | ≤2% of Sr at constant supply voltage and ambient temperature |
| Temperature drift | ±10% of Sr |
| Continuous current Ia | ≤100 mA |
| Off-state current | Typical 0.8 mA; ≤1.2 mA at maximum supply voltage and 100 °C |
| Minimum load current | ≥3 mA |
| Connection | 2 m two-wire PUR cable |
| Conductor cross-section | 0.34 mm² |
| Cable diameter | 4.5 mm |
| Wire assignments | CD-012: BN=L+; BU=M; load connected in series as shown in manufacturer circuit |
| Short-circuit protection | Provided |
| Power-up pulse | ≤5 ms |
| Housing material | V2A stainless steel; DIN 1.4305 / AISI 303 |
| Sensing face material | LCP plastic |
| Housing length | 50 mm |
| Thread length | 41 mm |
| Items supplied | Two V2A stainless-steel mounting nuts with locking teeth; 17 mm across flats |
| IP rating | IP68, EN 60529; IP69K, ISO 20653:2013-03 |
| Special features | Coolant-lubricant resistance; visual adjustment indicator; temperature resistance |
| Manufacturer application areas | Coolant/lubricant zones; mobile machines; difficult application conditions |
| Indicator | Visual adjustment indicator; see installation-aid diagram for Sr/Sa relationship |
| Installation clearances | Non-flush drawing: A=12 mm; B=24 mm; C=12 mm; D=24 mm; E=16 mm; F=64 mm; use with manufacturer installation graphic |
| Operating temperature | −40 to +100 °C |
| Shock and vibration resistance | 100 g / 2 ms / 500 cycles; 150 g / 1 million cycles; 10–55 Hz / 1 mm; 55–500 Hz / 60 g |
| Protection class | III |
| EMC | EN 60947-5-2 |
| UL file | E181493 |
| MTTFD | 1,287 years |
| DCavg | 0% |
| Material reduction factors | Reference values, may vary: St37 steel 1; V2A/304 stainless approximately 0.67; aluminum approximately 0.42; copper approximately 0.35; brass approximately 0.42 |
Industrial Applications
1. Confirming a machining clamp at its seated position
A machining fixture can present a metal clamp target to the non-flush sensing face when the clamp reaches its seated position. Coolant-lubricant resistance supports installation beside the machining area. External sequencing logic reads the two-wire NO circuit after settling, using an input matched to the minimum load current, off-state current and voltage drop and a gap established for the actual target material.
A clamp-position reference helps external sequencing logic distinguish a seated metal target from an open fixture condition, supporting a process check beside coolant-exposed machine tooling.
2. Counting metal flags on a moving mechanism
A moving mechanism can carry separated metal flags past the inductive sensing face and feed the two-wire switching circuit to external counting electronics. Target coverage, passing gap and material establish the usable detection condition. Commissioning checks flag spacing and speed against the 2,000 Hz rating and matches the counting input to the sensor’s load-current and voltage-drop characteristics.
A repeated metal-flag reference helps external counting electronics register mechanical events without contact, with flag presentation and electrical input matching established for the actual moving mechanism.
3. Setting a repeatable carrier-target sensing gap
During carrier-station setup, personnel can present the actual metal target and use the visual adjustment indicator with the manufacturer’s Sr/Sa installation-aid diagram to position the sensor. The 8 mm nominal and 6.48 mm assured ranges provide reference values, while material reduction factors and non-flush clearances inform the installed gap. The carrier is then repeatedly presented to check the resulting switching condition.
A local sensing-margin reference helps personnel establish a repeatable carrier-target presentation during commissioning, reducing dependence on the first observed switching point when positioning the inductive sensor.