Description
SICK GSE10-P4212 PNP Through-beam Sensor Pair
Technical Overview
The SICK GSE10-P4212 is a red-light through-beam photoelectric sensor pair with a 0–35 m sensing range and 0–40 m maximum range. The 625 nm PinPoint LED produces a 180 mm spot at 15 m. A 270° potentiometer adjusts the sensing condition, while a separate selector sets the receiver’s single PNP output to light or dark switching. Response is no more than 500 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The sender Test input turns illumination off at 0 V for an ordinary response check. IP67 ABS/PMMA housings use four-pin M12 connectors, and two BEF-G10DC01 mounting brackets are supplied.
Through-beam pair with 0–35 m sensing, selectable PNP light/dark output, sender Test, M12 four-pin connections and supplied mounting brackets.
Key Features
- Direct through-beam sensing from separate sender and receiver
- 0–35 m sensing range; 0–40 m maximum range
- 625 nm visible red PinPoint LED; Ø180 mm spot at 15 m
- 270° sensing adjustment and separate light/dark selector
- Single PNP output; output current ≤100 mA
- Response ≤500 µs with resistive load; 1,000 Hz at 1:1 light/dark ratio
- Sender Test input turns illumination off at 0 V
- M12 four-pin male connections; 10–30 V DC supply
- ABS/PMMA housing; IP67; −30 to +60 °C operation
- Two BEF-G10DC01 mounting brackets supplied
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Through-beam photoelectric sensor pair |
| Sensing range | 0–35 m |
| Maximum sensing range | 0–40 m |
| Light source | Visible red PinPoint LED; 625 nm |
| Average LED service life | 100,000 h at +25 °C |
| Light spot size | Ø180 mm at 15 m |
| Additional spot sizes | Ø15 mm at 0.1 m; Ø435 mm at 35 m; Ø501 mm at 40 m |
| Adjustment | Potentiometer, 270° |
| Switching output | Single PNP |
| Switching mode | Light/dark selected by separate selector |
| Output current | ≤100 mA |
| Response time | ≤500 µs signal transit time with resistive load |
| Switching frequency | 1,000 Hz at 1:1 light/dark ratio |
| Connection | M12 four-pin male connectors |
| Sender pin assignment | CD-073: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Test |
| Receiver pin assignment | CD-073: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Q |
| Test input | Sender OFF with Test at 0 V |
| Power supply | 10–30 V DC; short-circuit-protected network, maximum 8 A |
| Ripple | <5 Vpp; remain within supply-voltage tolerances |
| Sender current consumption | ≤15 mA |
| Receiver current consumption | ≤20 mA |
| Circuit protection | Supply and input/output reverse-polarity protection; interference suppression; output overcurrent and short-circuit protection |
| Protection class | III |
| Housing design | Rectangular |
| Housing material | ABS/PMMA plastic |
| IP rating | IP67 |
| Items supplied | Two BEF-G10DC01 mounting brackets |
| Mounting holes | Ø4.2 mm |
| Indication | Green: power on; yellow: received-light status |
| Operating temperature | −30 to +60 °C |
| Storage temperature | −40 to +70 °C |
| EMC | EN 60947-5-2 |
| UL file | NRKH.E348498 and NRKH7.E348498 |
| Conditional UL325 statement | Manufacturer states compliance when used with a sturdy protective hood, for example BEF-G10WSG, part 2071960 |
| MTTFD | 777 years |
| DCavg | 0% |
Industrial Applications
1. Counting opaque loads across a conveyor lane
A conveyor can place the sender and receiver on opposite sides of separated opaque loads. Each load interrupts the direct beam and gives external counting electronics a PNP transition. The 0–35 m sensing range accommodates the installed separation, while the response and 1,000 Hz switching specifications guide assessment of load coverage, spacing and passage timing.
Direct-beam interruptions give external counting electronics load-passage events, helping track separated articles without relying on light reflected from the article surface or a separate reflector.
2. Monitoring continuity of an opaque material web
A sheet or strip feeder can arrange the direct beam through a normally occupied material location. A broken or exhausted web clears the path and changes the receiver output. External monitoring times that clear state against normal feed motion and planned gaps, while the local light/dark selector adapts the signal to the controller’s ordinary input logic.
A sustained change in direct-beam reception gives external feed monitoring a continuity reference, helping recognize persistent material loss before a dependent processing operation continues.
3. Checking output response with the sender Test input
During a controlled machine check, external logic can drive sender Test to 0 V and observe the resulting receiver-output change. Turning off illumination creates a known optical interruption without moving a test article into the path. The controller evaluates the single PNP signal after the relevant response interval and then restores normal illumination.
A commanded optical interruption supplies ordinary external diagnostics with a repeatable stimulus, helping identify an absent or inconsistent receiver transition during a connected-input response check.