SICK 1065903 GSE10-P4212 PNP Through-beam Sensor Pair

USD 87.62

GSE10-P4212 offers 0–35 m through-beam sensing, PNP light/dark selection, 1,000 Hz, M12 four-pin connections, sender Test and two mounting brackets.

SKU: SICK-1065903 Category:

Description

SICK G10

SICK GSE10-P4212 PNP Through-beam Sensor Pair

BrandSICK
Model IdentifierGSE10-P4212
Official Part Number1065903

Technical Overview

The SICK GSE10-P4212 is a red-light through-beam photoelectric sensor pair with a 0–35 m sensing range and 0–40 m maximum range. The 625 nm PinPoint LED produces a 180 mm spot at 15 m. A 270° potentiometer adjusts the sensing condition, while a separate selector sets the receiver’s single PNP output to light or dark switching. Response is no more than 500 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The sender Test input turns illumination off at 0 V for an ordinary response check. IP67 ABS/PMMA housings use four-pin M12 connectors, and two BEF-G10DC01 mounting brackets are supplied.

Through-beam pair with 0–35 m sensing, selectable PNP light/dark output, sender Test, M12 four-pin connections and supplied mounting brackets.

Key Features

  • Direct through-beam sensing from separate sender and receiver
  • 0–35 m sensing range; 0–40 m maximum range
  • 625 nm visible red PinPoint LED; Ø180 mm spot at 15 m
  • 270° sensing adjustment and separate light/dark selector
  • Single PNP output; output current ≤100 mA
  • Response ≤500 µs with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • Sender Test input turns illumination off at 0 V
  • M12 four-pin male connections; 10–30 V DC supply
  • ABS/PMMA housing; IP67; −30 to +60 °C operation
  • Two BEF-G10DC01 mounting brackets supplied

Monitor direct-beam interruptions over a 0–35 m sensing path and use sender Test to provide an optical stimulus for ordinary output-response checks.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensor pair
Sensing range0–35 m
Maximum sensing range0–40 m
Light sourceVisible red PinPoint LED; 625 nm
Average LED service life100,000 h at +25 °C
Light spot sizeØ180 mm at 15 m
Additional spot sizesØ15 mm at 0.1 m; Ø435 mm at 35 m; Ø501 mm at 40 m
AdjustmentPotentiometer, 270°
Switching outputSingle PNP
Switching modeLight/dark selected by separate selector
Output current≤100 mA
Response time≤500 µs signal transit time with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
ConnectionM12 four-pin male connectors
Sender pin assignmentCD-073: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Test
Receiver pin assignmentCD-073: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Q
Test inputSender OFF with Test at 0 V
Power supply10–30 V DC; short-circuit-protected network, maximum 8 A
Ripple<5 Vpp; remain within supply-voltage tolerances
Sender current consumption≤15 mA
Receiver current consumption≤20 mA
Circuit protectionSupply and input/output reverse-polarity protection; interference suppression; output overcurrent and short-circuit protection
Protection classIII
Housing designRectangular
Housing materialABS/PMMA plastic
IP ratingIP67
Items suppliedTwo BEF-G10DC01 mounting brackets
Mounting holesØ4.2 mm
IndicationGreen: power on; yellow: received-light status
Operating temperature−30 to +60 °C
Storage temperature−40 to +70 °C
EMCEN 60947-5-2
UL fileNRKH.E348498 and NRKH7.E348498
Conditional UL325 statementManufacturer states compliance when used with a sturdy protective hood, for example BEF-G10WSG, part 2071960
MTTFD777 years
DCavg0%

Industrial Applications

1. Counting opaque loads across a conveyor lane

A conveyor can place the sender and receiver on opposite sides of separated opaque loads. Each load interrupts the direct beam and gives external counting electronics a PNP transition. The 0–35 m sensing range accommodates the installed separation, while the response and 1,000 Hz switching specifications guide assessment of load coverage, spacing and passage timing.

Problem Solved

Direct-beam interruptions give external counting electronics load-passage events, helping track separated articles without relying on light reflected from the article surface or a separate reflector.

Load count PNP output Direct beam

2. Monitoring continuity of an opaque material web

A sheet or strip feeder can arrange the direct beam through a normally occupied material location. A broken or exhausted web clears the path and changes the receiver output. External monitoring times that clear state against normal feed motion and planned gaps, while the local light/dark selector adapts the signal to the controller’s ordinary input logic.

Problem Solved

A sustained change in direct-beam reception gives external feed monitoring a continuity reference, helping recognize persistent material loss before a dependent processing operation continues.

Web continuity Light/dark selection External timing

3. Checking output response with the sender Test input

During a controlled machine check, external logic can drive sender Test to 0 V and observe the resulting receiver-output change. Turning off illumination creates a known optical interruption without moving a test article into the path. The controller evaluates the single PNP signal after the relevant response interval and then restores normal illumination.

Problem Solved

A commanded optical interruption supplies ordinary external diagnostics with a repeatable stimulus, helping identify an absent or inconsistent receiver transition during a connected-input response check.

Sender Test Response check Ordinary diagnostics

Additional information

Weight 0.166 kg