Description
Festo JMN1H-5/2-D-2-C ISO Solenoid Valve Body
Technical Overview
The Festo JMN1H-5/2-D-2-C is a 5/2-way bistable solenoid valve body with an ISO 5599-1 size 2 sub-base interface. N1 solenoid coils are ordered separately, so this body does not define a coil voltage. Internal pilot air supports operation from 2 to 10 bar, with non-reversible flow, 2300 l/min standard nominal flow and a specified 21 ms reversal time. The 54 mm-wide body has a 56 mm mounting grid pitch and weighs 940 g. Sub-base or through-hole mounting supports valve-station installation, while throttleable exhaust and a non-detenting manual override assist pneumatic setup.
ISO size 2 5/2-way bistable valve body with 2300 l/min nominal flow, internal pilot air and 21 ms reversal; N1 coils ordered separately.
Key Features
- 5/2-way bistable function with double-solenoid actuation
- ISO 5599-1 size 2 sub-base interface; ISO code 255
- N1 coils ordered separately; voltage depends on coil selection
- 2300 l/min standard nominal flow rate to DIN 1343
- 2–10 bar operating pressure with internal pilot air
- Non-reversible flow; not suitable for vacuum
- 54 mm construction width and 56 mm mounting grid pitch
- 21 ms specified switching reversal time
- Throttleable exhaust; non-detenting manual override and detenting via accessory
- 940 g die-cast aluminium body with HNBR/NBR seals
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, bistable; double-solenoid actuation |
| Type of actuation | Electrical |
| Construction width | 54 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 2300 l/min |
| pneumatic working port | Sub-base size 2 to ISO 5599-1; G3/8 |
| Operating voltage | Defined by separately selected solenoid coil; coil not included |
| Operating pressure | 0.2 MPa...1 MPa; 2 bar...10 bar |
| Design | Piston gate valve |
| Approval | c UL us - Recognised (Oil) |
| Maritime classification | See certificate |
| Certificate issuing authority | DNV-TAA000032X; UL MH19482 |
| Degree of protection | IP65 |
| Nominal size | 11.5 mm |
| Mounting grid pitch | 56 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Conforms to standard | ISO 5599-1 |
| Manual override | Detenting via accessory; Non-detenting |
| ISO code | 255 |
| Type of piloting | Piloted |
| Pilot air supply | Internal |
| Flow direction | Non-reversible |
| lap | Overlap |
| Suitability for vacuum | No |
| Switching time reversal | 21 ms |
| Max. positive test pulse with 0 signal | 3700 µs |
| Max. negative test pulse with 1 signal | 4600 µs |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | -5 °C...50 °C |
| Sound pressure level | 85 dB(A) |
| Ambient temperature | -5 °C...50 °C |
| Physical Weight (kg) | 0.94 |
| Electrical connection | Via separately selected N1 coil; coil not included |
| Type of mounting | On sub-base; Via through-hole and screw |
| Pilot exhaust port 82 | M5 |
| Pilot exhaust port 84 | M5 |
| Pneumatic connection, port 1 | Sub-base size 2 to ISO 5599-1 |
| Pneumatic connection, port 2 | Sub-base size 2 to ISO 5599-1 |
| Pneumatic connection, port 3 | Sub-base size 2 to ISO 5599-1 |
| Pneumatic connection, port 4 | Sub-base size 2 to ISO 5599-1 |
| Pneumatic connection, port 5 | Sub-base size 2 to ISO 5599-1 |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. ISO-Format Cylinder Directional Control
An assembly machine uses a double-acting cylinder that needs separate electrical commands for its two movement directions. This 5/2-way bistable body routes pressure and exhaust on an ISO 5599-1 size 2 sub-base, with 2300 l/min standard nominal flow. Its internally piloted arrangement operates at 2–10 bar, while the documented 21 ms reversal time characterises valve changeover.
Bistable five-port routing provides the two commanded cylinder directions, combining a standard ISO pneumatic interface with a documented reversal characteristic for the machine control sequence.
2. Cylinder Motion Setup with Exhaust Throttling
A pneumatic transfer mechanism requires exhaust-flow adjustment while its cylinder movement is being set up. Festo specifies that this valve body's exhaust air can be throttled, allowing suitable external flow-control components to meter the exhausting side of the circuit. Its non-detenting manual override also permits local valve actuation during pneumatic setup without requiring the normal electrical command.
Throttleable exhaust supports metering the cylinder exhaust path, while the local manual override gives the installer a direct actuation method during setup of the pneumatic mechanism.
3. Standardized Sub-Base Valve-Station Installation
A machine builder organises directional valves around ISO size 2 sub-base interfaces. The body conforms to ISO 5599-1 and has a 54 mm construction width with a 56 mm grid pitch, providing defined installation data for the station. Its separate N1 coil arrangement permits electrical actuation selection alongside the station wiring requirements without changing the valve-body identity.
Standardized mounting and a separately selected coil separate the pneumatic interface from the electrical selection, supporting a valve-station design with explicit connection and spacing requirements.