Description
Festo VMPA1-M1H-K-PI Dual Normally Closed Solenoid Valve
Technical Overview
The Festo VMPA1-M1H-K-PI combines two normally closed, monostable 3/2-way functions in a 10 mm valve with pneumatic spring reset. It operates at 24 V DC across a 3–10 bar working range, with non-reversible flow and a separate 3–8 bar pilot-pressure requirement. Standard nominal flow is 230 l/min, also specified for a QS-6 arrangement. Component switching times are 10 ms on and 20 ms off. The 56 g die-cast aluminium valve uses NBR seals and includes signal indication plus detenting/non-detenting manual override. Through-hole mounting has a 0.25 Nm maximum tightening torque; IP65 protection and −5 to 50 °C ambient/media limits characterize the assembly.
10 mm dual normally closed 3/2 valve with pneumatic spring reset, 230 l/min nominal flow, 24 V DC actuation and 3–10 bar working range.
Key Features
- Two normally closed monostable 3/2-way functions with pneumatic spring reset
- 10 mm soft-sealed piston-gate valve
- 230 l/min standard nominal flow, also specified with QS-6 arrangement
- 24 V DC operation with ±25% permissible voltage variation
- 3–10 bar working pressure and separate 3–8 bar pilot pressure
- Non-reversible flow direction; manufacturer excludes vacuum use
- 10 ms switch-on and 20 ms switch-off times
- Signal indication and detenting/non-detenting manual override
- IP65; through-hole mounting with 0.25 Nm maximum mounting torque
- 56 g aluminium body with NBR seals; −5 to 50 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 2x3/2 closed monostable |
| Type of actuation | Electrical |
| Valve size | 10 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 230 l/min |
| Operating voltage | 24 V DC |
| Operating pressure | 0.3 MPa...1 MPa; 3 bar...10 bar |
| Design | Piston gate valve |
| Type of reset | Pneumatic spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; To IEC 60529 |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Flow direction | Non-reversible |
| lap | Overlap |
| Signal status display | Yes |
| Pilot pressure | 0.3 MPa...0.8 MPa; 3 bar...8 bar |
| Suitability for vacuum | No |
| Standard nominal flow rate with QS-6 | 230 l/min |
| Switching time off | 20 ms |
| Switching time on | 10 ms |
| Max. positive test pulse with 0 signal | 400 µs |
| Max. negative test pulse with 1 signal | 200 µs |
| Permissible voltage fluctuations | +/-25% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -20 °C...40 °C |
| Media temperature | -5 °C...50 °C |
| Relative air humidity | Max. 90% at 40 °C |
| Ambient temperature | -5 °C...50 °C |
| Max. tightening torque for valve mounting | 0.25 Nm |
| Physical Weight (kg) | 0.056 |
| Type of mounting | With through-hole |
| Note on materials | RoHS compliant |
| Material seals | NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Fixture Clamp and Ejector Sequencing
An assembly fixture uses separate single-acting clamp and ejector circuits at different points in its cycle. The dual normally closed 3/2-way functions provide two pneumatic switching paths in one 10 mm body, with pneumatic spring reset. The 230 l/min nominal flow, 3–10 bar working range and separate 3–8 bar pilot pressure provide the selected valve data for the station.
Two monostable switching functions consolidate the clamp and ejector commands in one valve, supporting separate fixture steps with documented working and pilot pressure conditions.
2. Electrical Commands to Two Pneumatic Pilot Branches
A machine uses two downstream pneumatic control elements and needs separate electrically commanded pilot branches. This valve provides two normally closed monostable functions under 24 V DC actuation, with non-reversible working flow. Its 10 ms on and 20 ms off component times characterize the command stage, while the supplied pilot-air pressure must remain within the separate 3–8 bar range.
Two electrical-to-pneumatic switching paths provide individual commands for downstream control elements, consolidating their pilot-branch routing at one compact MPA valve position.
3. Valve-Station Commissioning
During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 10 mm valve uses through-hole mounting with a specified 0.25 Nm maximum valve-mounting torque for installation.
Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.