Description
SICK VTE180-2N42482 NPN Diffuse Photoelectric Sensor
Technical Overview
The SICK VTE180-2N42482 is an energetic photoelectric proximity sensor with axial visible-red illumination in an M18 × 1 cylindrical housing. Its 1–800 mm sensing range and 1–1,100 mm maximum range use 90% remission reference white; darker targets have shorter stated ranges. A 270° potentiometer adjusts sensing range, while control connection L/D selects light/dark switching for the NPN output. The sensor provides response of no more than 0.5 ms with resistive load and 1,000 Hz switching at a 1:1 light/dark ratio. Its four-pin M12 connector, nickel-plated brass/PC housing and PMMA optics support IP67 installation, with two fastening nuts supplied and operation from −25 to +55 °C.
M18 axial energetic sensor with 1–800 mm reference-white sensing, NPN output, L/D control input, 270° potentiometer and four-pin M12 connection.
Key Features
- Energetic photoelectric proximity sensing; axial M18 × 1 housing
- 1–800 mm sensing; 1–1,100 mm maximum range on 90% remission reference white
- 645 nm visible red LED; Ø30 mm spot at 800 mm
- 270° sensing-range potentiometer
- NPN output ≤100 mA; L/D control connection selects light/dark switching
- Control wire open: light switching L.ON
- ≤0.5 ms response with resistive load; 1,000 Hz at 1:1 light/dark ratio
- M12 four-pin male connector; 10–30 V DC; 30 mA without load
- Nickel-plated brass/PC housing; PMMA optics; two fastening nuts supplied
- IP67; −25 to +55 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Energetic photoelectric proximity sensing |
| Sensing range | 1–800 mm on 90% remission reference white, DIN 5033 |
| Maximum sensing range | 1–1,100 mm on 90% remission reference white, DIN 5033 |
| Reference-target ranges | Gray 18%: 5–400 mm sensing, 5–550 mm maximum; black 6%: 5–200 mm sensing, 5–300 mm maximum |
| Light source | Visible red LED |
| Wavelength | 645 nm |
| Light spot size | Ø30 mm at 800 mm |
| Angle of dispersion | Approx. 1.2° |
| LED service life | Average 100,000 h at +25 °C |
| Optical axis | Axial |
| Housing thread | M18 × 1 |
| Adjustment | 270° potentiometer for sensing range |
| Digital output | NPN; maximum output current ≤100 mA |
| Switching mode | Light/dark switching selected through L/D control connection; control wire open: light switching L.ON |
| Signal voltage HIGH/LOW | Approximately Vs / <1.8 V |
| Response time | ≤0.5 ms signal transit time with resistive load |
| Switching frequency | 1,000 Hz at 1:1 light/dark ratio |
| Connection | M12 four-pin male connector |
| Pin assignment | 1 BN=L+; 2 WH=L/D; 3 BU=M; 4 BK=Q (CD-087) |
| Power supply | 10–30 V DC, limit values; short-circuit-protected network maximum 8 A |
| Ripple | ±10%; remain within supply tolerances |
| Current consumption | 30 mA without load |
| Circuit protection | A: supply reverse-polarity protection; B: inputs and output reverse-polarity protection; D: output overcurrent and short-circuit protection |
| Protection class | III |
| Housing material | Nickel-plated brass and PC |
| Optics material | PMMA |
| IP rating | IP67 |
| Included accessories | Two fastening nuts, metal, 24 mm width across flats |
| Indicators | Orange: switching output active; green: signal-strength indicator |
| Operating temperature | −25 to +55 °C |
| Storage temperature | −40 to +70 °C |
| MTTFD | 1,889 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.047 |
Industrial Applications
1. Counting separated targets beside a component guide
A component guide can present separated targets to the sensor from one mounting side. The potentiometer establishes a reflected-light condition using representative targets, and external counting logic evaluates the NPN transitions. Setup checks actual target remission, gap and spacing against the applicable reference-target ranges, as well as the response and 1,000 Hz switching conditions at the intended speed.
A target-passage reference helps external counting logic register separated components from one mounting side, with sensitivity and electrical switching behavior commissioned for the actual target surface.
2. Checking an insert in a presented assembly nest
An assembly nest can hold an expected insert within a repeatable distance of the axial sensing face. The potentiometer sets sensitivity using representative assembled and empty nests, and external inspection logic samples the NPN state after positioning. Commissioning checks insert reflectance, background response and placement tolerance because energetic sensing evaluates returned light and depends on the presented optical surfaces.
A reflected-light presence condition helps external inspection logic check an expected insert at one monitored nest location, supporting an omitted-part indication after representative samples establish a usable signal difference.
3. Confirming a carrier at a transfer stop
A transfer station can bring a defined carrier surface into the adjusted sensing region when the carrier reaches its stop. External sequencing logic uses the NPN state as the monitored arrival condition, with L/D configured to suit the input logic. Setup checks seated gap, carrier remission, background and movement tolerance, using the shorter darker-target limits where appropriate.
A seated-carrier reference helps external transfer logic coordinate an ordinary process step using the observed arrival condition, with local sensitivity adjustment matched to the actual carrier surface.