Festo VUVS-L30-M32C-MZD-G38-F8-1B2 3/2-Way Solenoid Valve
Technical Overview
The Festo VUVS-L30-M32C-MZD-G38-F8-1B2 is a normally closed 3/2-way single-solenoid valve with G3/8 working connections and 24 V DC electrical actuation. External pilot air at 2.5–10 bar operates the piston gate valve, allowing the working circuit to cover −0.9 to 10 bar independently of its pilot supply. A mechanical spring provides reset, and the standard nominal flow rate is 2300 l/min. Reversible flow direction, throttleable exhaust and detenting or non-detenting manual override support circuit integration and commissioning. The 3.3 W coil permits continuous duty, while IP65 protection applies with a plug socket fitted.
Normally closed 3/2-way G3/8 solenoid valve with 24 V DC coil, external pilot supply and 2300 l/min standard nominal flow.
Key Features
- 3/2-way, single-solenoid, normally closed function
- 24 V DC, 3.3 W coil with 100% duty cycle
- G3/8 ports 1, 2 and 3; 31 mm valve size
- 2300 l/min standard nominal flow rate to DIN 1343
- −0.9 to 10 bar working pressure with external pilot air
- 2.5–10 bar pilot pressure; G1/8 pilot air port 12
- Mechanical spring reset and soft-sealing piston gate design
- Reversible flow direction and throttleable exhaust
- 16 ms switch-on and 58 ms switch-off times
- Type B electrical connection; IP65 with plug socket
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 3/2-way, single solenoid, closed |
| Type of actuation | Electrical |
| Valve size | 31 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 2300 l/min |
| pneumatic working port | G3/8 |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...1 MPa; -0.9 bar...10 bar |
| Design | Piston gate valve |
| Type of reset | Mechanical spring |
| Approval | c UL us - Recognised (Oil) |
| Maritime classification | See certificate |
| Certificate issuing authority | DNVGL-TAA000011J |
| Degree of protection | IP65; With plug socket; To IEC 60529 |
| Nominal size | 9.4 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Reversible |
| lap | Overlap |
| Pilot pressure | 0.25 MPa...1 MPa; 2.5 bar...10 bar |
| b value | 0.3 |
| C value | 9.9 l/sbar |
| Switching time off | 58 ms |
| Switching time on | 16 ms |
| Duty cycle | 100% |
| Max. positive test pulse with 0 signal | 2000 µs |
| Max. negative test pulse with 1 signal | 3600 µs |
| Characteristic coil data | 24 V DC: 3.3 W |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Cleanroom suitability, measured according to ISO 14644-14 | Class 6 according to ISO 14644-1 |
| Media temperature | -10 °C...60 °C |
| Pilot medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Ambient temperature | -10 °C...60 °C |
| Physical Weight (kg) | 0.405 |
| Electrical connection | Type B; To industry standard (11 mm) |
| Type of mounting | Either:; On manifold rail; With through-hole |
| Breather connection | Not ducted |
| Pilot exhaust port 82 | M5 |
| Pilot air port 12 | G1/8 |
| Pneumatic connection, port 1 | G3/8 |
| Pneumatic connection, port 2 | G3/8 |
| Pneumatic connection, port 3 | G3/8 |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Die-cast aluminium; painted |
| Material piston slide | Wrought aluminium alloy |
| Material screws | Nickel-plated steel |
Industrial Applications
1. Single-Acting Fixture Cylinder Control
A production fixture uses a single-acting cylinder that needs a controlled air supply and an exhaust path during its operating sequence. The valve's normally closed 3/2-way function provides the required switching arrangement, while its 24 V DC coil connects to the machine output circuit. Mechanical spring reset returns the valve when electrical actuation is removed.
One 3/2-way valve provides supply and exhaust switching for a single-acting pneumatic load, with electrical actuation and spring reset defining its commanded operating states.
2. Vacuum Circuit Connection Switching
A handling station needs to switch a vacuum line without depending on that line to power the valve pilot. This externally piloted model separates the 2.5–10 bar pilot supply from the working circuit, whose rated range extends to −0.9 bar. Reversible flow direction supports arranging the connections for the chosen vacuum switching circuit.
A separate compressed-air pilot operates the valve while its working ports handle sub-atmospheric pressure, addressing the lack of positive working pressure in vacuum-line switching.
3. Machine-Commanded Air-Blast Delivery
A transfer station applies an air blast to move a lightweight part or clear a tooling surface at a defined point in the sequence. The normally closed valve admits air when electrically commanded, with G3/8 connections and 2300 l/min standard nominal flow. Its continuous-duty coil also accommodates a maintained command when the process requires a longer air delivery period.
Electrical 3/2-way switching makes air delivery part of the machine sequence, while the documented nominal flow and continuous-duty coil support sizing for intermittent or maintained commands.