Description
Festo MHE2-M1H-3/2O-M7 Solenoid Valve
Technical Overview
The Festo MHE2-M1H-3/2O-M7 is a directly actuated 3/2-way normally open solenoid valve with mechanical spring reset. Its pressure-relief poppet design provides 100 l/min standard nominal flow through M7 connections, with a maximum switching frequency of 130 Hz. Specified switching times are 7 ms on and 3.5 ms off. The 24 V DC coil consumes 2.88 W and permits 100% duty cycle through a two-pin plug connection. Normal operation spans −0.9 to 8 bar, while reversed operation is restricted to −0.9 to 1 bar. The 60 g valve has IP65 protection, a non-detenting manual override and a 10 mm construction width.
24 V DC direct 3/2-way normally open M7 valve with 100 l/min nominal flow, 130 Hz maximum switching frequency and IP65 protection.
Key Features
- 3/2-way normally open function with mechanical spring reset
- Direct pressure-relief poppet design
- 100 l/min standard nominal flow to DIN 1343
- 130 Hz maximum switching frequency
- 7 ms switch-on and 3.5 ms switch-off times
- 24 V DC, 2.88 W coil and 100% duty cycle
- M7 ports and two-pin electrical plug connection
- −0.9 to 8 bar operating range; reversed operation limited to −0.9 to 1 bar
- IP65 protection and non-detenting manual override
- 10 mm construction width, 14 mm mounting grid pitch and 60 g product weight
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 3/2-way, single solenoid, open |
| Type of actuation | Electrical |
| Construction width | 10 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 100 l/min |
| pneumatic working port | M7 |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...0.8 MPa; -0.9 bar...8 bar; -13.05 psi...116 psi |
| Design | Pressure relief poppet valve |
| Type of reset | Mechanical spring |
| Degree of protection | IP65 |
| Approval | c UL us - Recognised (Oil) |
| Nominal size | 2 mm |
| Mounting grid pitch | 14 mm |
| Mounting grid note | Minimum distance between the valves is 4 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Non-detenting |
| Type of piloting | Direct |
| Flow direction | Reversible with restrictions |
| lap | Underlap |
| Operating pressure, reversible | -0.09 MPa...0.1 MPa; -0.9 bar...1 bar; -13.05 psi...14.5 psi |
| Max. switching frequency | 130 Hz |
| Switching time off | 3.5 ms |
| Switching time on | 7 ms |
| Duty cycle | 100% |
| Characteristic coil data | 24 V DC: 2.88 W |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Cleanroom suitability, measured according to ISO 14644-14 | Class 6 according to ISO 14644-1 |
| Media temperature | -5 °C...60 °C |
| Ambient temperature | -5 °C...60 °C |
| Physical Weight (kg) | 0.06 |
| Electrical connection | 2-pin; Plug |
| Type of mounting | With through-hole |
| Pneumatic connection, port 11 | M7 |
| Pneumatic connection, port 2 | M7 |
| Pneumatic port 33 | M7 |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Die-cast zinc, coated |
| Material screws | Galvanised steel |
Industrial Applications
1. Timed Interruption of a Pneumatic Air Line
A production station needs to interrupt an otherwise open pneumatic working line under electrical command. The valve's normally open 3/2 function provides the appropriate unenergized flow state, with mechanical spring reset after the command is removed. Its 7 ms on and 3.5 ms off component times, 100 l/min nominal flow and 130 Hz maximum switching frequency characterize the selected switching element without guaranteeing the complete line response.
The normally open directional function provides an electrical means of changing the working-line state, with documented switching times and flow capacity for evaluating the commanded interruption.
2. Energize-to-Vent Single-Acting Actuator Circuit
A fixture uses a single-acting pneumatic actuator whose circuit requires pressure in the valve's unenergized state and venting under an electrical command. The normally open 3/2 function supplies this directional arrangement, while mechanical spring reset restores the valve's normal state after de-energization. Its 24 V DC two-pin connection and 100% duty rating characterize the electrical interface for maintaining an energized valve command.
The normally open three-port arrangement provides the pressure and vent routing states for an energize-to-vent circuit, with mechanical spring return to the documented normal valve state.
3. Direct Switching of a Vacuum Branch
A vacuum-handling branch needs an electrically actuated valve without relying on a separate pilot-air pressure differential. The MHE2 uses direct actuation and has a documented negative-pressure operating range down to −0.9 bar. Flow reversal is permitted only with restrictions and a separate −0.9 to 1 bar range, so the vacuum circuit arrangement must follow that documented distinction rather than treating the valve as unrestricted in either direction.
Direct actuation supplies electrical switching for the negative-pressure circuit, while the explicit normal and reversed pressure ratings define the supported pneumatic arrangement of the branch.