Description
Festo VUVG-S14-P53E-ZT-G18-1T1L Solenoid Valve
Technical Overview
The Festo VUVG-S14-P53E-ZT-G18-1T1L is a 14 mm 5/3-way valve with an exhausted center and mechanical spring reset. G1/8 working ports provide 590 l/min standard nominal flow, with a −0.9 to 10 bar working range and separately supplied external pilot air at 3–8 bar. Its 24 V DC operating interface connects through an E-box; characteristic coil data separately specify 22 V DC and 1.0 W. Switching times are 15 ms on, 42 ms off and 25 ms reversal, with 3 Hz maximum switching frequency. The 95 g wrought-aluminium valve supports manifold-rail mounting, LED indication, manual override and IP65/IP67 protection.
14 mm 5/3-way exhausted-center valve with external pilot air, G1/8 working ports, E-box connection and 590 l/min nominal flow.
Key Features
- 5/3-way directional function with exhausted center
- 14 mm valve size and G1/8 working ports
- 590 l/min standard nominal flow to DIN 1343
- −0.9 to 10 bar working range and reversible flow direction
- External pilot-air supply at 3–8 bar
- Mechanical spring reset and manifold-rail mounting
- 24 V DC operating interface; coil data separately 22 V DC, 1.0 W
- 15 ms on, 42 ms off and 25 ms reversal; 3 Hz maximum switching frequency
- E-box electrical connection, LED indication and manual override
- 95 g product weight and IP65/IP67 protection
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/3 exhausted |
| Type of actuation | Electrical |
| Valve size | 14 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 590 l/min |
| pneumatic working port | G1/8 |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...1 MPa; -0.9 bar...10 bar |
| Design | Piston gate valve |
| Type of reset | Mechanical spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; IP67 |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Reversible |
| lap | Overlap |
| Signal status display | LED |
| Pilot pressure | 0.3 MPa...0.8 MPa; 3 bar...8 bar |
| Max. switching frequency | 3 Hz |
| Switching time off | 42 ms |
| Switching time on | 15 ms |
| Switching time reversal | 25 ms |
| Duty cycle | 100% |
| Max. positive test pulse with 0 signal | 1600 µs |
| Max. negative test pulse with 1 signal | 3000 µs |
| Characteristic coil data | 22 V DC: 1.0 W |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | -5 °C...60 °C |
| Pilot medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Ambient temperature | -5 °C...60 °C |
| Physical Weight (kg) | 0.095 |
| Electrical connection | Via E-box |
| Type of mounting | On manifold rail |
| Pneumatic connection, port 2 | G1/8 |
| Pneumatic connection, port 4 | G1/8 |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Wrought aluminium alloy |
Industrial Applications
1. Transfer Cylinder with a Vented Neutral Circuit State
A machine moves a suitable double-acting cylinder in two directions and needs a neutral valve state that connects the working lines to exhaust. The 5/3-way exhausted-center function provides those three routing states, and mechanical spring reset returns the valve to center. Its G1/8 connections and 590 l/min nominal flow characterize the selected component within the transfer circuit.
The exhausted center supplies a distinct vented routing state between directional commands, supporting a transfer circuit that requires working-line exhaust in its neutral pneumatic state.
2. Gripper Circuit with a Vented Release State
A handling fixture uses a double-acting gripper mechanism whose sequence includes working-line exhaust after opening or closing. The valve provides two directional states and an exhausted center, with external pilot air at 3–8 bar and a −0.9 to 10 bar working range. The center state vents the working lines; the gripper’s resulting movement or holding behavior depends on its own mechanical design.
Three-state air routing combines directional gripper commands with a working-line exhaust state, supporting a release sequence that explicitly requires venting at the valve’s neutral position.
3. Reversible Pneumatic Motor Routing
A machine uses a suitable reversible pneumatic motor and needs forward, reverse and vented-neutral air commands. The 5/3-way exhausted-center valve provides the required working-line routing through G1/8 ports, with a E-box connection for the control commands. Its specified 25 ms valve reversal time gives component timing information; motor run-down remains dependent on the drive and load.
One electrically commanded valve provides forward, reverse and vented-neutral routing, with a documented reversal time for evaluating the valve’s role in the pneumatic motor sequence.