Description
SICK WL100L-F2231 PNP Laser Retro-Reflective Sensor
Technical Overview
The SICK WL100L-F2231 is a polarized dual-lens laser retro-reflective sensor requiring a minimum reflector distance. It provides 0.08–10 m sensing with the supplied P250F reflector, with 0.08–12 m maximum range specified separately. The 650 nm Class 1 laser works with a 270° sensitivity potentiometer and a separate light/dark rotary switch. A single PNP output has response below 0.25 ms with resistive load and a 2,000 Hz switching rating at a 1:1 light/dark ratio. The ABS/PC housing uses PMMA optics, an M8 four-pin male connector and IP65 protection. A stainless steel mounting bracket is supplied.
Polarized laser retro-reflective sensor with 0.08–10 m P250F range, single PNP light/dark output, 2,000 Hz switching and M8 four-pin male connector.
Key Features
- Polarized dual-lens retro-reflective sensing; minimum reflector distance
- 0.08–10 m sensing; 0.08–12 m maximum with P250F
- 650 nm visible red Class 1 laser
- 270° sensitivity potentiometer; separate light/dark selector
- Single PNP output; response <0.25 ms with resistive load
- 2,000 Hz at 1:1 light/dark ratio
- 10–30 V DC; 30 mA without load; output current ≤100 mA
- M8 four-pin male connector; ABS/PC housing; PMMA optics; IP65
- Green power indicator; orange switching-output indicator
- BEF-W100-A stainless steel 1.4301/304 mounting bracket and P250F reflector supplied
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Polarized dual-lens retro-reflective photoelectric sensing |
| Sensing range | 0.08–10 m with P250F |
| Maximum sensing range | 0.08–12 m with P250F |
| Light source | Visible red laser; 650 nm |
| Laser class | 1 |
| Average laser service life | 50,000 h at +25 °C |
| Adjustment | Sensitivity potentiometer, 270° |
| Switching output | Single PNP |
| Switching mode | Light/dark switching selected by separate rotary switch |
| PNP signal HIGH/LOW | Supply voltage −1.8 V / approximately 0 V |
| Output current | ≤100 mA |
| Response time | <0.25 ms signal transit time with resistive load |
| Switching frequency | 2,000 Hz at 1:1 light/dark ratio |
| Power supply | 10–30 V DC; short-circuit-protected network, maximum 8 A |
| Ripple | ±10%; remain within supply-voltage tolerances |
| Current consumption | 30 mA without load |
| Connection | M8 four-pin male connector |
| Circuit protection | Supply and input/output reverse-polarity protection; output overcurrent and short-circuit protection |
| Housing design | Rectangular |
| Housing material | ABS/PC plastic |
| Optics material | PMMA plastic |
| IP rating | IP65 |
| Items supplied | BEF-W100-A stainless steel 1.4301/304 mounting bracket; P250F reflector |
| Mounting | M3 threaded holes; 25.4 mm spacing in drawing |
| Indication | Green: power on; orange: switching output active |
| Operating temperature | −10 to +50 °C |
| Storage temperature | −40 to +70 °C |
| Manufacturer special applications | Detecting small objects; detecting objects moving at high speeds |
| MTTFD | 438 years |
| DCavg | 0% |
| Pin assignment | CD-066: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Q |
| Reflector requirement | Dual-lens system with minimum reflector distance of 0.08 m |
| Polarizing filter | Provided |
| Other reflector ranges | PL20F: 0.08–8.5 m sensing, 0.08–10 m maximum; PL10F: 0.08–6.5 m sensing, 0.08–8 m maximum |
| Physical Weight (kg) | 0.01 |
Industrial Applications
1. Counting opaque packages through a reflector path
A conveyor can place the supplied P250F reflector opposite the sensor and pass separated opaque packages through the returned-light path. Each interruption changes the single PNP output for an external counter. Commissioning maintains at least 0.08 m reflector separation and checks target coverage and spacing against the response below 0.25 ms and 2,000 Hz switching specification.
Returned-light interruptions give external counting electronics package-passage events, helping count separated opaque loads with the optical sender and receiver combined at one sensor location.
2. Monitoring continuity of an opaque material feed
An opaque web feeder can place the reflector path across a location normally occupied by the material. A broken or exhausted web clears the path and changes the selected PNP light/dark state. External monitoring times the clear condition to distinguish sustained material loss from planned gaps, with sensitivity adjustment and the local output indicator supporting setup of the optical arrangement.
A sustained optical-state change gives external feed monitoring a continuity reference, helping identify a break or exhausted material before a dependent operation proceeds without the intended web.
3. Timing occupancy at a conveyor handoff
A conveyor handoff can place the reflector path across its receiving location so an opaque load interrupts the beam while that location remains occupied. External control measures the interruption duration against normal transfer time. The P250F sensing range accommodates the installed separation, and the separate light/dark selector sets the output state expected by the controller.
Timing a sustained beam interruption gives external handoff control an occupancy reference, helping coordinate upstream release when the receiving location remains filled.