$ 156.40
Inosaki – Your Trusted Phoenix Contact Distributor
Inosaki proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.
Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.
Discover industry-leading Phoenix Contact power supplies, such as:
Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@inosaki.com to request your Phoenix Contact catalog.
UNO POWER power supplies with basic functionality
Thanks to their high power density, compact UNO POWER power supplies are the ideal solution for loads up to 240 W, particularly in compact control boxes. The power supply units are available in various performance classes and overall widths. Their high degree of efficiency and low idling losses ensure a high level of energy efficiency.
Width | 55 mm |
---|---|
Height | 90 mm |
Depth | 84 mm |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 30 mm / 30 mm |
Degree of protection | IP20 |
---|---|
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Ambient temperature (operation) | -25 °C … 70 °C (> 55 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Nominal input voltage range | 2x 400 VÂ AC … 500 VÂ AC |
---|---|
Input voltage range | 2x 264 VÂ AC … 575 VÂ AC |
Extended input voltage range in operation | 2x 264 VÂ AC … 320 VÂ AC (Derating 10 %) |
Frequency range (fN) | 50 Hz … 60 Hz 10 % |
Current consumption | typ. 0.55 A (400Â VÂ AC) |
typ. 0.48 A (500 VÂ AC) | |
Nominal power consumption | 211.3 VA |
Inrush current | < 30 A (typ.) |
Mains buffering time | > 65 ms (400Â VÂ AC) |
> 100 ms (500 VÂ AC) | |
Input fuse | 2 A (slow-blow, internal) |
Recommended breaker for input protection | 6 A … 16 A (Characteristics B, C, D, K) |
Power factor (cos phi) | 0.48 |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Nominal output voltage | 24 V DC ±1 % |
---|---|
Nominal output current (IN) | 3.75 A |
3.38 A (Derating 10 %) | |
Derating | 55 °C … 70 °C (2.5%/K) |
Connection in parallel | no |
Connection in series | No |
Feedback voltage resistance | < 35 VÂ DC |
Protection against overvoltage at the output (OVP) | ≤ 35 V DC |
Control deviation | < 1 % (change in load, static 10 % … 90 %) |
< 3 % (Dynamic load change 10 % … 90 %, 10 Hz) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 50 mVPPÂ (with nominal values) |
Output power | 90 W |
Maximum power dissipation in no-load condition | < 0.7 W |
Power loss nominal load max. | < 12 W |
Article Number | 2904371 |
---|---|
Net weight | 0.32 kg |
Efficiency | typ. 89 % (400Â VÂ AC) |
typ. 89 % (480Â VÂ AC) | |
MTBF (IEC 61709, SN 29500) | > 828000 h (40 °C) |
Insulation voltage input/output | 4 kV AC (type test) |
3 kV AC (routine test) | |
Degree of protection | IP20 |
Protection class | II (in closed control cabinet) |
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Housing material | Polycarbonate |
Foot latch material | POM (Polyoxymethylene) |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: 0Â mm horizontally, 30Â mm vertically |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 8 mm |
Screw thread | M3 |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 8 mm |
Screw thread | M3 |
EMC requirements for noise immunity | ENÂ 61000-6-1 |
---|---|
ENÂ 61000-6-2 | |
EMC requirements for noise emission | ENÂ 61000-6-3 |
ENÂ 61000-6-4 | |
Standard – Safety of transformers | ENÂ 61558-2-16 |
Standard – Electrical safety | IECÂ 62368-1Â (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
Standard – Safe isolation | DINÂ VDEÂ 0100-410 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Mains variation/undervoltage | ENÂ 61000-4-11 |
UL approvals | UL/C-UL listed UL 508 |
---|---|
NEC Class 2 as per UL 1310 | |
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) | |
UL/C-UL Recognized UL 60950-1 | |
CSA | CAN/CSA-C22.2 No. 60950-1-07 |
CSA-C22.2 No. 107.1-01 | |
CAN/CSA-C22.2 No. 213 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Electromagnetic HF field | ENÂ 61000-4-3 |
Frequency range | 80 MHz … 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 1 GHz … 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | ENÂ 61000-4-4 |
Input | 4 kV (Test Level 4 – asymmetrical) |
Output | 2 kV (Test Level 3 – asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge) | ENÂ 61000-4-5 |
Input | 2 kV (Test Level 3 – symmetrical) |
4 kV (Test Level 4 – asymmetrical) | |
Output | 1 kV (Test Level 2 – symmetrical) |
2 kV (Test Level 3 – asymmetrical) | |
Comments | Criterion B |
Conducted interference | ENÂ 61000-4-6 |
Frequency range | 10 kHz … 80 MHz |
Voltage | 10 V (Test Level 3) |
Comments | Criterion A |
Voltage dips | ENÂ 61000-4-11 |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 25; |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |