$ 72.16
Phoenix Contact develops terminal blocks, distribution blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Item number | 3273834 |
Packing unit | 8 pc |
Minimum order quantity | 8 pc |
Product key | BEA115 |
Catalog page | Page 447 (C-1-2019) |
GTIN | 4055626714547 |
Weight per piece (including packing) | 41.8 g |
Weight per piece (excluding packing) | 38.732 g |
Customs tariff number | 85369010 |
Country of origin | PL |
General | |
Note | The maximum load current of a single clamping unit must not be exceeded. |
Product Properties
Product type | Distributor terminal block |
Number of connections | 18 |
Number of rows | 1 |
Potentials | 1 |
Insulation characteristics | |
Overvoltage category | III |
Degree of pollution | 3 |
Rated surge voltage | 6 kV |
Maximum power dissipation for nominal condition | 1.02 W |
Connection Data
Number of connections per level | 18 |
Nominal cross section | 4 mm² |
Rated cross section AWG | 18 |
Stripping length | 10 mm … 12 mm |
Internal cylindrical gage | A4 |
Connection in acc. with standard | IEC 60998-2-2 |
Conductor cross section rigid | 0.2 mm² … 6 mm² |
Cross section AWG | 24 … 10 (converted acc. to IEC) |
Conductor cross section flexible | 0.2 mm² … 6 mm² |
Conductor cross section, flexible [AWG] | 24 … 10 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.2 mm² … 4 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.2 mm² … 4 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² … 1 mm² |
Nominal current | 32 A |
Maximum load current | 41 A |
Maximum total current | 63 A |
Nominal voltage | 450 V |
Connection cross sections directly pluggable | |
Conductor cross section rigid | 0.5 mm² … 6 mm² |
Conductor cross section, rigid [AWG] | 20 … 10 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.75 mm² … 4 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² … 4 mm² |
Width | 55.4 mm |
Height | 28.6 mm |
Depth | 21.7 mm |
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 |
Insulating material group | I |
Insulating material | PA |
Static insulating material application in cold | -60 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Mechanical data | |
Open side panel | No |
Attachment on the carrier | |
Result | Test passed |
Note | When aligning several blocks, it is recommended to either place a DIN rail adapter underneath the connection point or a flange element between the blocks. |
For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block. | |
When using the DIN rail adapter PTFIX-NS35, an aligned block must not protrude by more than a half. |
Needle-flame test | |
Time of exposure | 30 s |
Result | Test passed |
Oscillation/broadband noise | |
Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
Spectrum | Long life test category 2, bogie-mounted |
Frequency | f1 = 5 Hz to f2 = 250 Hz |
ASD level | 6.12 (m/s²)²/Hz |
Acceleration | 3.12g |
Test duration per axis | 5 h |
Test directions | X-, Y- and Z-axis |
Result | Test passed |
Shocks | |
Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
Pulse shape | Half-sine |
Acceleration | 30g |
Shock duration | 18 ms |
Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) |
Result | Test passed |
Ambient conditions | |
Ambient temperature (operation) | -60 °C … 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
Ambient temperature (storage/transport) | -25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Ambient temperature (assembly) | -5 °C … 70 °C |
Ambient temperature (actuation) | -5 °C … 70 °C |
Permissible humidity (operation) | 20 % … 90 % |
Permissible humidity (storage/transport) | 30 % … 70 % |
Connection in acc. with standard | IEC 60998-2-2 |
Mounting type | for snapping onto a DIN rail adapter |
Direct mounting with flange | |
Free-hanging |
Weight | N/A |
---|---|
MOQ(pcs) |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)