Contact Us:
sales@inosaki.com

KCD2-SR-Ex1.LB – Safety Integrity Level 2 – PEPPERL+FUCHS SIL-Capable Products for Hazardous Areas

$ 123.51

General Specifications

Signal type Digital Input

Functional safety related parameters

Safety Integrity Level (SIL) SIL 2
Systematic capability (SC) SC 3

Supply

Connection Power Rail or terminals 9+, 10-
Rated voltage Ur 19 … 30 V DC
Ripple ≤ 10 %
Rated current Ir ≤ 37 mA
Power dissipation ≤ 750 mW
Power consumption ≤ 750 mW

Input

Connection side field side
Connection terminals 1+, 2-
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 … 2.1 mA / approx. 0.2 mA
Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Pulse/Pause ratio min. 20 ms / min. 20 ms

Output

Connection side control side
Connection output I: terminals 5, 6 ; output II: terminals 7, 8
Output I signal ; relay
Output II signal or fault message ; relay
Contact loading 250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
Minimum switch current 2 mA / 24 V DC
Energized/De-energized delay ≤ 20 ms / ≤ 20 ms
Mechanical life 107 switching cycles

Transfer characteristics

Switching frequency ≤ 10 Hz

Galvanic isolation

Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elements LEDs
Control elements DIP switch
Configuration via DIP switches
Labeling space for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010+A1:2019+A1:2019/AC:2019

Conformity

Electromagnetic compatibility NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
Degree of protection IEC 60529:1989+A1:1999+A2:2013
Functional safety IEC/EN 61508:2010
Input EN 60947-5-6:2000

Ambient conditions

Ambient temperature -40 … 70 °C (-40 … 158 °F)

Mechanical Specifications

Degree of protection IP20
Connection screw terminals
Mass approx. 100 g
Dimensions 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height 119 mm
Width 12.5 mm
Depth 114 mm
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificate BASEEFA 06 ATEX 0092 X
Marking Ex-Hexagon II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc , [exsign] II (1)D [Ex ia Da] IIIC , [exsign] I (M1) [Ex ia Ma] I
Input Ex ia
Voltage Uo 10.5 V
Current Io 13 mA
Power Po 34 mW (linear characteristic)
Supply
Maximum safe voltage Um 253 V AC (Attention! Um is no rated voltage.)
Output
Contact loading Zone 2 : 50 V AC/2 A/cos φ > 0.75; 30 V DC/2 A resistive load
Maximum safe voltage Um 253 V AC (Attention! The rated voltage can be lower.)
Fault indication output
Maximum safe voltage Um 40 V DC (Attention! Um is no rated voltage.)
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019

International approvals

UL approval E106378
Control drawing 116-0477 (cULus)
IECEx approval
IECEx certificate IECEx BAS 06.0025 X
IECEx marking Ex ec nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I

General information

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Additional information

Weight 0.100 kg
Dimensions 11.4 × 1.25 × 11.9 cm