$ 6,599.85
General information | |
Product type designation | CPU 1516-3 PN/DP |
HW functional status | FS04 |
Firmware version ● FW update possible |
V4.0 Yes |
Product function | |
● I&M data ● Isochronous mode ● SysLog |
Yes; I&M0 to I&M3 Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central) Yes |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V20 (FW V4.0) / V18 (FW V3.0) or higher; configurable with older TIA Portal versions as 6ES7516-3AN02-0AB0 |
Configuration control | |
via dataset | Yes |
Display | |
Screen diagonal [cm] | 6.1 cm |
Control elements | |
Number of keys | 8 |
Mode buttons | 2 |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering | |
● Mains/voltage failure stored energy time ● Repeat rate, min. |
5ms 1/s |
Input current | |
Current consumption (rated value) | 0.69 A |
Current consumption, max. | 1.08 A |
Inrush current, max. | 1.15 A; Rated value |
I²t | 0.6 A²·s |
Power | |
Infeed power to the backplane bus | 12 W |
Power consumption from the backplane bus (balanced) | 6.7 W |
Power loss | |
Power loss, typ. | 4 W |
Memory | |
Number of slots for SIMATIC memory card | 1 |
SIMATIC memory card required | Yes |
Work memory | |
● integrated (for program) ● integrated (for data) |
2 Mbyte 7.5 Mbyte |
Load memory | |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup | |
● maintenance-free | Yes |
CPU processing times | |
for bit operations, typ. | 6 ns |
for word operations, typ. | 7 ns |
for fixed point arithmetic, typ. | 9 ns |
for floating point arithmetic, typ. | 37 ns |
CPU-blocks | |
Number of elements (total) | 8 000; Blocks (OB, FB, FC, DB) and UDTs |
DB | |
● Number range
● Size, max. |
1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999 7.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
FB | |
● Number range ● Size, max. |
0 … 65 535 1 Mbyte |
FC | |
● Number range ● Size, max. |
0 … 65 535 1 Mbyte |
OB | |
● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of isochronous mode OBs ● Number of technology synchronous alarm OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs ● Number of diagnostic alarm OBs |
1 Mbyte 100 20 20 20; With minimum OB 3x cycle of 250 µs 50 3 3 2 100 4 2 1 |
Nesting depth | |
● per priority class | 24 |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 2048 |
Retentivity | |
— adjustable | Yes |
IEC counter | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
S7 times | |
● Number | 2048 |
Retentivity | |
— adjustable | Yes |
IEC timer | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB |
Extended retentive data area (incl. timers, counters, flags), max. | 7.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
Flag | |
● Size, max. ● Number of clock memories |
16 kbyte 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks | |
● Retentivity adjustable ● Retentivity preset |
Yes No |
Local data | |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area | |
Number of IO modules | 8 192; max. number of modules / submodules |
I/O address area | |
● Inputs ● Outputs |
32 kbyte; All inputs are in the process image 32 kbyte; All outputs are in the process image |
per integrated IO subsystem | |
— Inputs (volume) — Outputs (volume) |
8 kbyte 8 kbyte |
per CM/CP | |
— Inputs (volume) — Outputs (volume) |
8 kbyte 8 kbyte |
Subprocess images | |
● Number of subprocess images, max. | 32 |
Hardware configuration | |
Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
Number of DP masters | |
● integrated ● Via CM |
1 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Number of IO Controllers | |
● integrated ● Via CM |
2 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Rack | |
● Modules per rack, max. ● Number of lines, max. |
32; CPU + 31 modules 1 |
PtP CM | |
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day | |
Clock | |
● Type ● Backup time ● Deviation per day, max. |
Hardware clock 6 wk; At 40 °C ambient temperature, typically 10 s; Typ.: 2 s |
Operating hours counter | |
● Number | 16 |
Clock synchronization | |
● supported ● to DP, master ● on DP, device ● in AS, master ● in AS, device ● on Ethernet via NTP |
Yes Yes Yes; via PROFIBUS CM / CP Yes Yes Yes |
Interfaces | |
Number of PROFINET interfaces | 2 |
Number of PROFIBUS interfaces | 1 |
1. Interface | |
Interface types | |
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes;X1 2 Yes |
Protocols | |
● IP protocol ● PROFINET IO Controller ● PROFINET IO Device ● SIMATIC communication ● Open IE communication ● Web server ● Media redundancy |
Yes; IPv4 Yes Yes Yes Yes; Optionally also encrypted Yes Yes |
PROFINET IO Controller | |
Services | |
— Isochronous mode — Direct data exchange — IRT — PROFIenergy — Prioritized startup — Number of connectable IO Devices, max. — Of which IO devices with IRT, max. — PROFINET Security Class |
Yes Yes; Requirement: IRT and isochronous mode (MRPD optional) Yes Yes; per user program Yes; Max. 32 PROFINET devices 256; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET 64 256 256 8; in total across all interfaces 8 |
Update time for IRT | |
— for send cycle of 250 µs
— for send cycle of 500 µs |
250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive 500 µs to 8 ms 1 ms to 16 ms 2 ms to 32 ms 4 ms to 64 ms Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) |
Update time for RT | |
— for send cycle of 250 µs — for send cycle of 500 µs — for send cycle of 1 ms — for send cycle of 2 ms — for send cycle of 4 ms |
250 µs to 128 ms 500 µs to 256 ms 1 ms to 512 ms 2 ms to 512 ms 4 ms to 512 ms |
PROFINET IO Device | |
Services | |
— Isochronous mode — IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. — activation/deactivation of I-devices — Asset management record — PROFINET Security Class |
No Yes Yes; per user program Yes 4 Yes; per user program Yes; per user program SNMP Configuration and DCP Read Only |
2. Interface | |
Interface types | |
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes; X2 1 No |
Protocols | |
● IP protocol ● PROFINET IO Controller ● PROFINET IO Device ● SIMATIC communication ● Open IE communication ● Web server ● Media redundancy |
Yes; IPv4 Yes Yes Yes Yes; Optionally also encrypted Yes No |
PROFINET IO Controller | |
Services | |
— Isochronous mode — Direct data exchange — IRT — PROFIenergy — Prioritized startup — Number of connectable IO Devices, max. — Number of connectable IO Devices for RT, max. — PROFINET Security Class |
No No No Yes; per user program No 32; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET 32 32 8; in total across all interfaces 8 |
Update time for IRT | |
— for send cycle of 250 µs
— for send cycle of 500 µs |
250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive 500 µs to 8 ms 1 ms to 16 ms 2 ms to 32 ms 4 ms to 64 ms Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) |
Update time for RT | |
— for send cycle of 250 µs — for send cycle of 500 µs — for send cycle of 1 ms — for send cycle of 2 ms — for send cycle of 4 ms |
250 µs to 128 ms 500 µs to 256 ms 1 ms to 512 ms 2 ms to 512 ms 4 ms to 512 ms |
PROFINET IO Device | |
Services | |
— Isochronous mode — IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. — activation/deactivation of I-devices — Asset management record — PROFINET Security Class |
No Yes Yes; per user program Yes 4 Yes; per user program Yes; per user program SNMP Configuration and DCP Read Only |
Interface types | |
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes; X2 1 No |
Protocols | |
● IP protocol ● PROFINET IO Controller ● PROFINET IO Device ● SIMATIC communication ● Open IE communication ● Web server ● Media redundancy |
Yes; IPv4 Yes Yes Yes Yes; Optionally also encrypted Yes No |
PROFINET IO Controller | |
Services | |
— Isochronous mode — Direct data exchange — IRT — PROFIenergy — Prioritized startup — Number of connectable IO Devices, max. — Number of connectable IO Devices for RT, max. — PROFINET Security Class |
No No No Yes; per user program No 32; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET 32 32 8; in total across all interfaces 8 |
Update time for RT | |
— for send cycle of 1 ms | 1 ms to 512 ms |
PROFINET IO Device | |
Services | |
— Isochronous mode — IRT — PROFIenergy — Prioritized startup — Shared device — Number of IO Controllers with shared device, max. — activation/deactivation of I-devices — Asset management record — PROFINET Security Class |
No No Yes; per user program No Yes 4 Yes; per user program Yes; per user program SNMP Configuration and DCP Read Only |
3. Interface | |
Interface types | |
● RS 485 ● Number of ports |
Yes; X3 1 |
Protocols | |
● PROFIBUS DP master ● PROFIBUS DP device ● SIMATIC communication |
Yes No Yes |
PROFIBUS DP master | |
● Number of connections, max. ● max. number of DP devices |
48; for the integrated PROFIBUS DP interface 125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
Services | |
— Equidistance — Isochronous mode — activation/deactivation of DP devices |
Yes Yes Yes |
Interface types | |
RJ 45 (Ethernet) | |
● 100 Mbps ● Autonegotiation ● Autocrossing ● Industrial Ethernet status LED |
Yes Yes Yes Yes |
RS 485 | |
● Transmission rate, max. | 12 Mbit/s |
Protocols | |
PROFIsafe | No |
Number of connections | |
● Number of connections, max. ● Number of connections reserved for ES/HMI/web ● Number of connections via integrated interfaces ● Number of S7 routing paths |
256; via integrated interfaces of the CPU and connected CPs / CMs 10 128 16 |
Redundancy mode | |
● H-Sync forwarding | Yes |
Media redundancy | |
— Media redundancy — MRP — MRP interconnection, supported |
only via 1st interface (X1) Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 Yes; Requirement: IRT 200 ms; For MRP, bumpless for MRPD 50 |
SIMATIC communication | |
● PG/OP communication ● S7 routing ● Data record routing ● S7 communication, as server ● S7 communication, as client ● User data per job, max. |
Yes; encryption with TLS V1.3 pre-selected Yes Yes Yes Yes See online help (S7 communication, user data size) |
Open IE communication | |
● TCP/IP — Data length, max. — several passive connections per port, supported ● ISO-on-TCP (RFC1006) — Data length, max. ● UDP — Data length, max. — UDP multicast ● DHCP ● DNS ● SNMP ● DCP ● LLDP ● Encryption |
Yes 64 kbyte Yes Yes 64 kbyte Yes 2 kbyte; 1 472 bytes for UDP broadcast Yes; max. 118 multicast circuits Yes Yes Yes Yes Yes Yes; Optional |
Web server | |
● HTTP ● HTTPS ● web API — Number of sessions, max. — number of simultaneous HTTP calls, max. 4 — HTTP request body, max. |
Yes; Standard and user pages Yes; Standard and user pages 100 |
OPC UA | |
● Runtime license required ● OPC UA Client — Application authentication — Security policies — User authentication |
Yes; “Medium” license required Yes; Data Access (registered Read/Write), Method Call Yes Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 “anonymous” or by user name & password 10 2000 300 20 100 1 |
instructions for session management, per connection, max. — Number of simultaneous calls of the client instructions for data access, per connection, max. — Number of registerable nodes, max. — Number of registerable method calls of OPC_UA_MethodCall, max. — Number of inputs/outputs when calling OPC_UA_MethodCall, max. |
5 5000 20 |
● OPC UA Server | Yes; data access (read, write, subscribe), method call, alarms & condition (A&C), custom address space, role-based access control |
— Application authentication — Security policies — User authentication — Number of inputs/outputs per server method, max. — Number of nodes for user-defined server interfaces, |
Yes available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss “anonymous” or by user name & password Yes 48 100 000 20 000 50 100 ms 100 ms 50; max. 20 concurrently running jobs each for asynchronous instructions OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost 20 4 000; for 1 s sampling interval and 1 s send interval 10 of each “Server interfaces” / “Companion specification” type and 20 of the type “Reference namespace” 30 000 Yes |
Further protocols | |
● MODBUS | Yes; MODBUS TCP |
Isochronous mode | |
Equidistance | Yes |
S7 message functions | |
Number of login stations for message functions, max. | 64 |
number of subscriptions, max. | 500 |
number of tags/attributes for subscriptions, max. | 8 000 |
Program alarms | Yes |
Number of configurable program messages, max. | 10 000; Program messages are generated by the “Program_Alarm” block, ProDiag or GRAPH |
Number of loadable program messages in RUN, max. | 10 000 |
Number of simultaneously active program alarms ● Number of program alarms ● Number of alarms for system diagnostics ● Number of alarms for motion technology objects |
1 000 200 160 |
Test commissioning functions | |
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
Single step | No |
Number of breakpoints | 8 |
Profiling | Yes |
Status/control | |
● Status/control variable ● Variables ● Number of variables, max. — of which status variables, max. — of which control variables, max |
Yes Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 200; per job |
Forcing | |
● Forcing ● Forcing, variables ● Number of variables, max. |
Yes Peripheral inputs/outputs 200 |
Diagnostic buffer | |
● present ● Number of entries, max. — of which powerfail-proof |
Yes 3200 500 |
Traces | |
● Number of configurable Traces ● Memory size per trace, max. |
4 512 kbyte |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
● RUN/STOP LED ● ERROR LED ● MAINT LED ● STOP ACTIVE LED ● Connection display LINK TX/RX |
Yes Yes Yes Yes Yes |
Supported technology objects | |
Motion Control
● Number of available Motion Control resources for |
Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool 2 400 40 11 20 |
Controller ● PID_Compact ● PID_3Step ● PID-Temp |
Yes; Universal PID controller with integrated optimization Yes; PID controller with integrated optimization for valves Yes; PID controller with integrated optimization for temperature |
Counting and measuring ● High-speed counter |
Yes |
Standards, approvals, certificates | |
Siemens Eco Profile (SEP) | Siemens EcoTech |
Ecological footprint | |
● environmental product declaration | Yes |
Global warming potential | |
— global warming potential, (total) [CO2 eq] — global warming potential, (during production) [CO2 eq] — global warming potential, (during operation) [CO2 eq] — global warming potential, (after end of life cycle) [CO2 eq] |
102kg 26.5kg 76.7kg -0.898kg |
product functions / security / header | |
PROFINET Security Class | 1 |
signed firmware update | Yes |
Secure Boot | Yes |
safely removing data | Yes |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. |
-30 °C; No condensation 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off -30 °C; No condensation 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
Ambient temperature during storage/transportation | |
● min. ● max. |
-40 °C 70 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD — FBD — STL — SCL — CFC — GRAPH |
Yes Yes Yes Yes Yes Yes |
Know-how protection | |
● User program protection/password protection ● Copy protection ● Block protection |
Yes Yes Yes |
Access protection | |
● protection of confidential configuration data ● Password for display ● Protection level: Write protection ● Protection level: Read/write protection ● Protection level: Write protection for Failsafe ● Protection level: Complete protection ● User administration ● Number of users ● Number of groups ● Number of roles |
Yes Yes Yes Yes No Yes Yes; device-wide and centralized 100 100 50 |
programming / cycle time monitoring / header | |
● lower limit ● upper limit |
adjustable minimum cycle time adjustable maximum cycle time |
Dimensions | |
Width | 70 mm |
Height | 147 mm |
Depth | 129 mm |
Weights | |
Weight, approx. | 469 g |
Weight | 0.524 kg |
---|---|
Dimensions | 15.5 × 15.8 × 8 cm |