SIMATIC S7-1500 – CPU 1516-3 PN/DP – Central Processing Unit – Siemens Advanced Contollers

$ 6,599.85

SKU 6ES7516-3AP03-0AB0 Category

Specifications

General information
Product type designation CPU 1516-3 PN/DP
HW functional status FS04
 Firmware version
● FW update possible
V4.0
Yes
Product function
● I&M data
● Isochronous mode

● SysLog

Yes; I&M0 to I&M3
Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed)
and 1 ms (central)
Yes
Engineering with
 ● STEP 7 TIA Portal configurable/integrated from version  V20 (FW V4.0) / V18 (FW V3.0) or higher; configurable with older TIA Portal
versions as 6ES7516-3AN02-0AB0
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 8
Mode buttons 2
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
 ● Mains/voltage failure stored energy time
● Repeat rate, min.
5ms
1/s
Input current
Current consumption (rated value)  0.69 A
Current consumption, max.  1.08 A
Inrush current, max. 1.15 A; Rated value
 I²t  0.6 A²·s
Power
Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 6.7 W
Power loss
Power loss, typ. 4 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program)
● integrated (for data)
2 Mbyte
7.5 Mbyte
Load memory
 ● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 6 ns
for word operations, typ. 7 ns
for fixed point arithmetic, typ. 9 ns
for floating point arithmetic, typ. 37 ns
CPU-blocks
Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range

● Size, max.

 1 … 60 999; subdivided into: number range that can be used by the user: 1 …
59 999, and number range of DBs created via SFC 86: 60 000 … 60 999
7.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range
● Size, max.
0 … 65 535
1 Mbyte
FC
● Number range
● Size, max.
0 … 65 535
1 Mbyte
OB
● Size, max.
● Number of free cycle OBs
● Number of time alarm OBs
● Number of delay alarm OBs
● Number of cyclic interrupt OBs
● Number of process alarm OBs
● Number of DPV1 alarm OBs
● Number of isochronous mode OBs
● Number of technology synchronous alarm OBs
● Number of startup OBs
● Number of asynchronous error OBs
● Number of synchronous error OBs
● Number of diagnostic alarm OBs
1 Mbyte
100
20
20
20; With minimum OB 3x cycle of 250 µs
50
3
3
2
100
4
2
1
Nesting depth
 ● per priority class 24
Counters, timers and their retentivity
S7 counter
 ● Number 2048
 Retentivity
— adjustable Yes
 IEC counter
 ● Number  Any (only limited by the main memory)
 Retentivity
— adjustable Yes
 S7 times
 ● Number 2048
 Retentivity
— adjustable Yes
IEC timer
 ● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers,
counters, DBs, and technology data (axes): 472 KB
 Extended retentive data area (incl. timers, counters, flags), max.  7.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF
 Flag
● Size, max.
● Number of clock memories
16 kbyte
8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable
● Retentivity preset
Yes
No
 Local data
 ● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 8 192; max. number of modules / submodules
I/O address area
 ● Inputs
● Outputs
32 kbyte; All inputs are in the process image
32 kbyte; All outputs are in the process image
per integrated IO subsystem
 — Inputs (volume)
— Outputs (volume)
8 kbyte
8 kbyte
per CM/CP
 — Inputs (volume)
— Outputs (volume)
8 kbyte
8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Hardware configuration
Number of distributed IO systems  64; A distributed I/O system is characterized not only by the integration of
distributed I/O via PROFINET or PROFIBUS communication modules, but also
by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● integrated
● Via CM
1
8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be
inserted in total
Number of IO Controllers
● integrated
● Via CM
2
8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be
inserted in total
Rack
● Modules per rack, max.
● Number of lines, max.
32; CPU + 31 modules
1
 PtP CM
 ● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available
slots
Time of day
 Clock
 ● Type
● Backup time
● Deviation per day, max.
Hardware clock
6 wk; At 40 °C ambient temperature, typically
10 s; Typ.: 2 s
 Operating hours counter
 ● Number 16
Clock synchronization
● supported
● to DP, master
● on DP, device
● in AS, master
● in AS, device
● on Ethernet via NTP
Yes
Yes
Yes; via PROFIBUS CM / CP
Yes
Yes
Yes
Interfaces
Number of PROFINET interfaces 2
Number of PROFIBUS interfaces 1
1. Interface
Interface types
● RJ 45 (Ethernet)
● Number of ports
● integrated switch
Yes;X1
2
Yes
Protocols
● IP protocol
● PROFINET IO Controller
● PROFINET IO Device
● SIMATIC communication
● Open IE communication
● Web server
● Media redundancy
Yes; IPv4
Yes
Yes
Yes
Yes; Optionally also encrypted
Yes
Yes
PROFINET IO Controller
Services
 — Isochronous mode
— Direct data exchange
— IRT
— PROFIenergy
— Prioritized startup
— Number of connectable IO Devices, max.

— Of which IO devices with IRT, max.
— Number of connectable IO Devices for RT, max.
— of which in line, max.
— Number of IO Devices that can be simultaneously
activated/deactivated, max.
— Number of IO Devices per tool, max.
— Updating times

— PROFINET Security Class

Yes
Yes; Requirement: IRT and isochronous mode (MRPD optional)
Yes
Yes; per user program
Yes; Max. 32 PROFINET devices
256; in total, up to 1024 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
64
256
256
8; in total across all interfaces

8
The minimum value of the update time also depends on communication share
set for PROFINET IO, on the number of IO devices, and on the quantity of
configured user data
1

 Update time for IRT
— for send cycle of 250 µs

— for send cycle of 500 µs
— for send cycle of 1 ms
— for send cycle of 2 ms
— for send cycle of 4 ms
— With IRT and parameterization of “odd” send cycles

250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum
update time of 375 µs of the isochronous OB is decisive
500 µs to 8 ms
1 ms to 16 ms
2 ms to 32 ms
4 ms to 64 ms
Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3
875 µs)
Update time for RT
 — for send cycle of 250 µs
— for send cycle of 500 µs
— for send cycle of 1 ms
— for send cycle of 2 ms
— for send cycle of 4 ms
250 µs to 128 ms
500 µs to 256 ms
1 ms to 512 ms
2 ms to 512 ms
4 ms to 512 ms
 PROFINET IO Device
Services
 — Isochronous mode
— IRT
— PROFIenergy
— Shared device
— Number of IO Controllers with shared device, max.
— activation/deactivation of I-devices
— Asset management record
— PROFINET Security Class
No
Yes
Yes; per user program
Yes
4
Yes; per user program
Yes; per user program
SNMP Configuration and DCP Read Only
2. Interface
 Interface types
● RJ 45 (Ethernet)
● Number of ports
● integrated switch
Yes; X2
1
No
Protocols
● IP protocol
● PROFINET IO Controller
● PROFINET IO Device
● SIMATIC communication
● Open IE communication
● Web server
● Media redundancy
Yes; IPv4
Yes
Yes
Yes
Yes; Optionally also encrypted
Yes
No
PROFINET IO Controller
Services
 — Isochronous mode
— Direct data exchange
— IRT
— PROFIenergy
— Prioritized startup
— Number of connectable IO Devices, max.

— Number of connectable IO Devices for RT, max.
— of which in line, max.
— Number of IO Devices that can be simultaneously
activated/deactivated, max.
— Number of IO Devices per tool, max.
— Updating times

— PROFINET Security Class

No
No
No
Yes; per user program
No
32; in total, up to 1024 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
32
32
8; in total across all interfaces

8
The minimum value of the update time also depends on communication share
set for PROFINET IO, on the number of IO devices, and on the quantity of
configured user data
1

Update time for IRT
— for send cycle of 250 µs

— for send cycle of 500 µs
— for send cycle of 1 ms
— for send cycle of 2 ms
— for send cycle of 4 ms
— With IRT and parameterization of “odd” send cycles

 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum
update time of 375 µs of the isochronous OB is decisive
500 µs to 8 ms
1 ms to 16 ms
2 ms to 32 ms
4 ms to 64 ms
Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3
875 µs)
 Update time for RT
 — for send cycle of 250 µs
— for send cycle of 500 µs
— for send cycle of 1 ms
— for send cycle of 2 ms
— for send cycle of 4 ms
 250 µs to 128 ms
500 µs to 256 ms
1 ms to 512 ms
2 ms to 512 ms
4 ms to 512 ms
 PROFINET IO Device
 Services
— Isochronous mode
— IRT
— PROFIenergy
— Shared device
— Number of IO Controllers with shared device, max.
— activation/deactivation of I-devices
— Asset management record
— PROFINET Security Class
No
Yes
Yes; per user program
Yes
4
Yes; per user program
Yes; per user program
SNMP Configuration and DCP Read Only
Interface types
● RJ 45 (Ethernet)
● Number of ports
● integrated switch
Yes; X2
1
No
Protocols
● IP protocol
● PROFINET IO Controller
● PROFINET IO Device
● SIMATIC communication
● Open IE communication
● Web server
● Media redundancy
Yes; IPv4
Yes
Yes
Yes
Yes; Optionally also encrypted
Yes
No
PROFINET IO Controller
Services
— Isochronous mode
— Direct data exchange
— IRT
— PROFIenergy
— Prioritized startup
— Number of connectable IO Devices, max.

— Number of connectable IO Devices for RT, max.
— of which in line, max.
— Number of IO Devices that can be simultaneously
activated/deactivated, max.
— Number of IO Devices per tool, max.
— Updating times

— PROFINET Security Class

No
No
No
Yes; per user program
No
32; in total, up to 1024 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
32
32
8; in total across all interfaces

8
The minimum value of the update time also depends on communication share
set for PROFINET IO, on the number of IO devices, and on the quantity of
configured user data
1

Update time for RT
— for send cycle of 1 ms 1 ms to 512 ms
PROFINET IO Device
Services
— Isochronous mode
— IRT
— PROFIenergy
— Prioritized startup
— Shared device
— Number of IO Controllers with shared device, max.
— activation/deactivation of I-devices
— Asset management record
— PROFINET Security Class
No
No
Yes; per user program
No
Yes
4
Yes; per user program
Yes; per user program
SNMP Configuration and DCP Read Only
3. Interface
Interface types
● RS 485
● Number of ports
Yes; X3
1
Protocols
● PROFIBUS DP master
● PROFIBUS DP device
● SIMATIC communication
Yes
No
Yes
PROFIBUS DP master
● Number of connections, max.
● max. number of DP devices
48; for the integrated PROFIBUS DP interface
125; In total, up to 1 000 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
Services
— Equidistance
— Isochronous mode
— activation/deactivation of DP devices
Yes
Yes
Yes
Interface types
RJ 45 (Ethernet)
● 100 Mbps
● Autonegotiation
● Autocrossing
● Industrial Ethernet status LED
Yes
Yes
Yes
Yes
RS 485
● Transmission rate, max. 12 Mbit/s
Protocols
PROFIsafe No
Number of connections
● Number of connections, max.
● Number of connections reserved for ES/HMI/web
● Number of connections via integrated interfaces
● Number of S7 routing paths
256; via integrated interfaces of the CPU and connected CPs / CMs
10
128
16
Redundancy mode
● H-Sync forwarding Yes
Media redundancy
— Media redundancy
— MRP

— MRP interconnection, supported
— MRPD
— Switchover time on line break, typ.
— Number of stations in the ring, max.

only via 1st interface (X1)
Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager;
MRP Client
Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
Yes; Requirement: IRT
200 ms; For MRP, bumpless for MRPD
50
SIMATIC communication
● PG/OP communication
● S7 routing
● Data record routing
● S7 communication, as server
● S7 communication, as client
● User data per job, max.
Yes; encryption with TLS V1.3 pre-selected
Yes
Yes
Yes
Yes
See online help (S7 communication, user data size)
Open IE communication
● TCP/IP
— Data length, max.
— several passive connections per port, supported
● ISO-on-TCP (RFC1006)
— Data length, max.
● UDP
— Data length, max.
— UDP multicast
● DHCP
● DNS
● SNMP
● DCP
● LLDP
● Encryption
Yes
64 kbyte
Yes
Yes
64 kbyte
Yes
2 kbyte; 1 472 bytes for UDP broadcast
Yes; max. 118 multicast circuits
Yes
Yes
Yes
Yes
Yes
Yes; Optional
Web server
● HTTP
● HTTPS
● web API
— Number of sessions, max.
— number of simultaneous HTTP calls, max. 4
— HTTP request body, max.
Yes; Standard and user pages
Yes; Standard and user pages

100
4
131 072 byte

OPC UA
● Runtime license required
● OPC UA Client
— Application authentication
— Security policies

— User authentication
— Number of connections, max.
— Number of nodes of the client interfaces,
recommended max.
— Number of elements for one call of
OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList,
max.
— Number of elements for one call of
OPC_UA_NameSpaceGetIndexList, max.
— Number of elements for one call of
OPC_UA_MethodGetHandleList, max.
— Number of simultaneous calls of the client

Yes; “Medium” license required
Yes; Data Access (registered Read/Write), Method Call
Yes
Available security policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
“anonymous” or by user name & password
10
2000

300

20

100

1

instructions for session management, per connection,
max.
— Number of simultaneous calls of the client
instructions for data access, per connection, max.
— Number of registerable nodes, max.
— Number of registerable method calls of
OPC_UA_MethodCall, max.
— Number of inputs/outputs when calling
OPC_UA_MethodCall, max.

5

5000
100

20

● OPC UA Server Yes; data access (read, write, subscribe), method call, alarms & condition
(A&C), custom address space, role-based access control
— Application authentication
— Security policies

— User authentication
— GDS support (certificate management)
— Number of sessions, max.
— Number of accessible variables, max.
— Number of registerable nodes, max.
— Number of subscriptions per session, max.
— Sampling interval, min.
— Publishing interval, min.
— Number of server methods, max.

— Number of inputs/outputs per server method, max.
— Number of monitored items, recommended max.
— Number of server interfaces, max.

— Number of nodes for user-defined server interfaces,
max.
● Alarms and Conditions
— Number of program alarms
— Number of alarms for system diagnostics

Yes
available security policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
“anonymous” or by user name & password
Yes
48
100 000
20 000
50
100 ms
100 ms
50; max. 20 concurrently running jobs each for asynchronous instructions
OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost
20
4 000; for 1 s sampling interval and 1 s send interval
10 of each “Server interfaces” / “Companion specification” type and 20 of the
type “Reference namespace”
30 000

Yes
200
100

Further protocols
● MODBUS Yes; MODBUS TCP
Isochronous mode
Equidistance Yes
S7 message functions
Number of login stations for message functions, max. 64
number of subscriptions, max. 500
number of tags/attributes for subscriptions, max. 8 000
Program alarms Yes
Number of configurable program messages, max. 10 000; Program messages are generated by the “Program_Alarm” block,
ProDiag or GRAPH
Number of loadable program messages in RUN, max. 10 000
Number of simultaneously active program alarms
● Number of program alarms
● Number of alarms for system diagnostics
● Number of alarms for motion technology objects
1 000
200
160
Test commissioning functions
Joint commission (Team Engineering) Yes; Parallel online access possible for up to 8 engineering systems
Status block Yes; Up to 8 simultaneously (in total across all ES clients)
Single step No
Number of breakpoints 8
Profiling Yes
Status/control
● Status/control variable
● Variables
● Number of variables, max.
— of which status variables, max.
— of which control variables, max
Yes
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

200; per job
200; per job

Forcing
● Forcing
● Forcing, variables
● Number of variables, max.
Yes
Peripheral inputs/outputs
200
Diagnostic buffer
● present
● Number of entries, max.
— of which powerfail-proof
Yes
3200
500
Traces
● Number of configurable Traces
● Memory size per trace, max.
4
512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED
● ERROR LED
● MAINT LED
● STOP ACTIVE LED
● Connection display LINK TX/RX
Yes
Yes
Yes
Yes
Yes
Supported technology objects
Motion Control

● Number of available Motion Control resources for
technology objects
● Required Motion Control resources
— per speed-controlled axis
— per positioning axis
— per synchronous axis
— per external encoder
— per output cam
— per cam track
— per probe
● Positioning axis
— Number of positioning axes at motion control cycle
of 4 ms (typical value)
— Number of positioning axes at motion control cycle
of 8 ms (typical value)

Yes; Note: The number of technology objects affects the cycle time of the PLC
program; selection guide via the TIA Selection Tool
2 400

40
80
160
80
20
160
40

11

20

Controller
● PID_Compact
● PID_3Step
● PID-Temp
Yes; Universal PID controller with integrated optimization
Yes; PID controller with integrated optimization for valves
Yes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counter
Yes
Standards, approvals, certificates
Siemens Eco Profile (SEP) Siemens EcoTech
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq]
— global warming potential, (during production) [CO2
eq]
— global warming potential, (during operation) [CO2
eq]
— global warming potential, (after end of life cycle)
[CO2 eq]
102kg
26.5kg

76.7kg

-0.898kg

product functions / security / header
PROFINET Security Class 1
signed firmware update Yes
Secure Boot Yes
safely removing data Yes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.
● horizontal installation, max.

● vertical installation, min.
● vertical installation, max.

-30 °C; No condensation
60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the
display is switched off
-30 °C; No condensation
40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the
display is switched off
Ambient temperature during storage/transportation
● min.
● max.
-40 °C
70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
— LAD
— FBD
— STL
— SCL
— CFC
— GRAPH
Yes
Yes
Yes
Yes
Yes
Yes
Know-how protection
● User program protection/password protection
● Copy protection
● Block protection
Yes
Yes
Yes
Access protection
● protection of confidential configuration data
● Password for display
● Protection level: Write protection
● Protection level: Read/write protection
● Protection level: Write protection for Failsafe
● Protection level: Complete protection
● User administration
● Number of users
● Number of groups
● Number of roles
Yes
Yes
Yes
Yes
No
Yes
Yes; device-wide and centralized
100
100
50
programming / cycle time monitoring / header
● lower limit
● upper limit
adjustable minimum cycle time
adjustable maximum cycle time
Dimensions
Width 70 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 469 g

Additional information

Weight 0.524 kg
Dimensions 15.5 × 15.8 × 8 cm