Specifications

Main
Part Number LC1D25M7 LC1D25B7C LC1D25BDC LC1D25CC7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive load, resistance furnace Applied to non-inductive or micro-inductive load, resistance furnace Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-1
AC-3
AC-4
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 25 A 60 °C) at <= 440 V AC AC-3 for power circuits
40 A 60 °C) at <= 440 V AC AC-1 for power circuits
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-1 for power circuit
25 A 60 °C) at <= 440 V AC AC-3 for power circuit
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-1 for power circuit
25 A 60 °C) at <= 440 V AC AC-3 for power circuit
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-1 for power circuit
25 A 60 °C) at <= 440 V AC AC-3 for power circuit
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 230V AC 50/60Hz 24 V AC 50/60 Hz 24 V DC 36 V AC 50/60 Hz
Additional information
Motor power (kW) 5.5 kW at 220…230 V AC 50/60 Hz (AC-3)
11 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 415.. .440 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3)
15 kW at 660…690 V AC 50/60 Hz (AC-3 )
5.5 kW at 400 V AC 50/60 Hz (AC-4)
5.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
11 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 415…440 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3e)
15 kW at 660…690 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3)
11 kW at 380/400 V AC 50/60 Hz (AC-3)
11 kW at 415/440 V AC 50/60 Hz (AC-3)
15 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3e)
11 kW at 380/400 V AC 50/60 Hz (AC-3e)
11 kW at 415/440 V AC 50/60 Hz (AC-3e)
15 kW at 660/690 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3)
11 kW at 380/400 V AC 50/60 Hz (AC-3)
11 kW at 415/440 V AC 50/60 Hz (AC-3)
15 kW at 660/690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
15 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3e)
11 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
11 kW at 415/440 V AC 50/60 Hz (AC-3e)
15 kW at 660/690 V AC 50/60 Hz (AC -3e)
15 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3)
11 kW at 380/400 V AC 50/60 Hz (AC-3)
11 kW at 415/440 V AC 50/60 Hz (AC-3)
15 kW at 660/690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
15 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3e)
11 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
11 kW at 415/440 V AC 50/60 Hz (AC-3e)
15 kW at 660/690 V AC 50/60 Hz (AC -3e)
Motor Power 3 hp at 230/240 V AC 50/60 Hz for 1-phase motors
2 hp at 115 V AC 50/60 Hz for 1-phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 Phase motor
15 hp at 460/480 V AC 50/60 Hz for 3 phase motor
20 hp at 575/600 V AC 50/60 Hz for 3 phase motor
7.5 hp at 200/208 V AC 50/ 60 Hz for 3-phase motors
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
Contactor Compatibility Features M2
protection cap Bring None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
Rated making capacity [Irms] 140 A AC for signal circuits according to IEC 60947-5-1
250 A DC for signal circuits according to IEC 60947-5-1
450 A at 440 V for power circuits according to IEC 60947
Rated breaking capacity 450 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
average impedance 2 mΩ – Ith 40 A 50 Hz for power circuits 2 mΩ – Ith 40 A 50 Hz for power circuits 2 mΩ – Ith 40 A 50 Hz for power circuits 2 mΩ – Ith 40 A 50 Hz for power circuits
power consumption per pole 3.2W AC-1
1.25W AC-3
1.25W AC-3e
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 15 Mcycles 15 Mcycles 30 Mcycles 15 Mcycles
Electrical life 1.65 Mcycles 25 A AC-3 Ue <= 440 V
1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.65 Mcycles 25 A AC-3e Ue <= 440 V
1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.6 Mcycles 25 A AC-3 Ue <= 440 V
2 Mcycles 17 A AC-3 Ue 660/690 V
1.6 Mcycles 25 A AC-3e Ue <= 440 V at
2 Mcycles 17 A AC-3e at 660/690 V at Ue
1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.6 Mcycles 25 A AC-3 Ue <= 440 V
2 Mcycles 17 A AC-3 Ue 660/690 V
1.6 Mcycles 25 A AC-3e Ue <= 440 V at
2 Mcycles 17 A AC-3e at 660/690 V at Ue
1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.6 Mcycles 25 A AC-3 Ue <= 440 V
2 Mcycles 17 A AC-3 Ue 660/690 V
1.6 Mcycles 25 A AC-3e Ue <= 440 V at
2 Mcycles 17 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz standard AC at 50/60 Hz DC standard AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module Built-in bidirectional peak current limiting diode No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…70 °C Release AC 50/60 Hz
0.8…1.1 Uc -40…60 °C Run AC 50 Hz
0.85…1.1 Uc -40…60 °C Run AC 60 Hz
1…1.1 Uc 60…70 °C Operation AC 50/60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.1…0.25 Uc -40…60 °C release
0.7…1.25 Uc -40…60 °C run
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
heat dissipation 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz
action time 12…22 ms close
4…19 ms break
12…22 ms close
4…19 ms break
55 ms to close,
20 ms to break
12…22 ms close
4…19 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Hard wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable option: Hard wire without wire terminal
Power circuit: Bolt tight1 2.5…10 mm² Cable option: Flexible wire without wire Wire terminal
power circuit: screw-on2 2.5…10 mm² Cable option: flexible without cable terminal
Power circuit: screw-on1 1…10 mm² cable option: flexible with cable terminal
Power circuit: screw-on Solid2 1.5…6 mm² Cable option: flexible cable with wire terminals Power
circuit: screw fastened1 1.5…10 mm² Cable option: solid without cable terminals
Power circuit: screw screwed2 2.5…10 mm² cable Type selection: hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 1.5…10 mm² Lug outer diameter Ø: 10 mm Cable Selection: Flexible cord without wire terminals
Power circuit: Bolt fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable selection: Flexible cord without wire terminal
Power circuit: Bolt fastening1 1…6 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cable with wire terminals
Power circuit: screw fastening2 1…4 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cable with cable terminal Power
circuit : Bolt fastening1 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 1.5…10 mm² Lug outer diameter Ø: 10 mm Cable Selection: Flexible cord without wire terminals
Power circuit: Bolt fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable selection: Flexible cord without wire terminal
Power circuit: Bolt fastening1 1…6 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cable with wire terminals
Power circuit: screw fastening2 1…4 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cable with cable terminal Power
circuit : Bolt fastening1 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 1.5…10 mm² Lug outer diameter Ø: 10 mm Cable Selection: Flexible cord without wire terminals
Power circuit: Bolt fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable selection: Flexible cord without wire terminal
Power circuit: Bolt fastening1 1…6 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cable with wire terminals
Power circuit: screw fastening2 1…4 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cable with cable terminal Power
circuit : Bolt fastening1 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Tightening torque Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for tightening Phillips screw
Control circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts
Power circuit: 2.5 Nm Screwdriver pozidriv No. 2 for tightening via bolts
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade via cable connector: M4 Power circuit:
2.5 Nm Phillips screw via cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Fastening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz 25…400Hz
Minimum switching voltage 17 V for signal return 17 V for signal return 17 V for signal return 17 V for signal return
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
environment
standard CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product BV
GL
LROS (Lloyds register of shipping)
GOST
UL
DNV
CCC
CSA
RINA
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP20 front panel conforming to IEC 60529 IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
climate tolerance Complies with IACS E10 for exposure to hot flashes
Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes
ambient air temperature -40…60 °C
60…70 °C with derating
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 0…3000m 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
flame retardant V1 complies with UL 94
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz))
shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance
with contacts closed (15 gn (11ms))
Shock performance Contact opening (8 gn (11ms))
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
high 85 mm 85 mm 85 mm 85 mm
width 45 mm 45 mm 45 mm 45 mm
depth 92 mm 92 mm 101 mm 92 mm
Product Weight 0.37kg 0.37 kg 0.37 kg 0.37kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5cm 5.153 cm 5.8cm 5.436 cm
Package 1 Width 9.3 cm 8.724 cm 8.8cm 8.942 cm
Package 1 Length 11.4 cm 9.79cm 11.1 cm 10.024 cm
Package 1 Weight 410g 424.0g 581.0g 401.0g
Unit Type of Package 2 S02 S02 CAR S02
Number of Units in Package 2 20 Twenty one 20 Twenty one
Package 2 Height 15cm 15.0cm 14.5cm 15.0cm
Package 2 Width 30cm 30.0cm 29.0cm 30.0cm
Package 2 Length 40cm 40.0cm 39.4 cm 40.0cm
Package 2 Weight 8.503kg 9.179kg 12.006kg 9.07kg
Unit Type of Package 3 P06 PAL PAL PAL
Number of Units in Package 3 320 336 320 336
Package 3 Height 75cm 60.0cm 60.0cm 60.0cm
Package 3 Width 60cm 80.0cm 80.0cm 80.0cm
Package 3 Length 80cm 75.0cm 75.0cm 75.0cm
Package 3 Weight 143kg 150.944 kg 204.688kg 142.949 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number LC1D25E7C LC1D25F7C LC1D25Q7C
Product Series TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor
product short name LC1D LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 40 A 60 °C) at <= 440 V AC AC-1 for power circuit
25 A 60 °C) at <= 440 V AC AC-3 for power circuit
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-1 for power circuit
25 A 60 °C) at <= 440 V AC AC-3 for power circuit
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-1 for power circuit
25 A 60 °C) at <= 440 V AC AC-3 for power circuit
25 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz 110V AC 50/60Hz 110V AC 50/60Hz
Additional information
Motor power (kW) 15 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3)
11 kW at 380/400 V AC 50/60 Hz (AC-3)
11 kW at 415/440 V AC 50/60 Hz (AC-3)
15 kW at 660/690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
15 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3e)
11 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
11 kW at 415/440 V AC 50/60 Hz (AC-3e)
15 kW at 660/690 V AC 50/60 Hz (AC -3e)
15 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3)
11 kW at 380/400 V AC 50/60 Hz (AC-3)
11 kW at 415/440 V AC 50/60 Hz (AC-3)
15 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3e)
11 kW at 380/400 V AC 50/60 Hz (AC-3e)
11 kW at 415/440 V AC 50/60 Hz (AC-3e)
15 kW at 660/690 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3)
11 kW at 380/400 V AC 50/60 Hz (AC-3)
11 kW at 415/440 V AC 50/60 Hz (AC-3)
15 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 220/240 V AC 50/60 Hz (AC-3e)
11 kW at 380/400 V AC 50/60 Hz (AC-3e)
11 kW at 415/440 V AC 50/60 Hz (AC-3e)
15 kW at 660/690 V AC 50/60 Hz (AC-3e)
model LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO
protection cap None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
40 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
40 A gG for power circuits for type 2 at <= 690 V
average impedance 2 mΩ – Ith 40 A 50 Hz for power circuits 2 mΩ – Ith 40 A 50 Hz for power circuits 2 mΩ – Ith 40 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 15 Mcycles 15 Mcycles 15 Mcycles
Electrical life 1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.6 Mcycles 25 A AC-3 Ue <= 440 V
2 Mcycles 17 A AC-3 Ue 660/690 V
1.6 Mcycles 25 A AC-3e Ue <= 440 V at
2 Mcycles 17 A AC-3e at 660/690 V at Ue
1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.6 Mcycles 25 A AC-3 Ue <= 440 V
2 Mcycles 17 A AC-3 Ue 660/690 V
1.6 Mcycles 25 A AC-3e Ue <= 440 V at
2 Mcycles 17 A AC-3e at 660/690 V at Ue
1.4 Mcycles 40 A AC-1 Ue <= 440 V
1.6 Mcycles 25 A AC-3 Ue <= 440 V
2 Mcycles 17 A AC-3 Ue 660/690 V
1.6 Mcycles 25 A AC-3e Ue <= 440 V at
2 Mcycles 17 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
heat dissipation 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz
action time 12…22 ms close
4…19 ms break
12…22 ms close
4…19 ms break
12…22 ms close
4…19 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 1.5…10 mm² Lug outer diameter Ø: 10 mm Cable Selection: Flexible cord without wire terminals
Power circuit: Bolt fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable selection: Flexible cord without wire terminal
Power circuit: Bolt fastening1 1…6 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cable with wire terminals
Power circuit: screw fastening2 1…4 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cable with cable terminal Power
circuit : Bolt fastening1 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 1.5…10 mm² Lug outer diameter Ø: 10 mm Cable Selection: Flexible cord without wire terminals
Power circuit: Bolt fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable selection: Flexible cord without wire terminal
Power circuit: Bolt fastening1 1…6 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cable with wire terminals
Power circuit: screw fastening2 1…4 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cable with cable terminal Power
circuit : Bolt fastening1 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 1.5…10 mm² Lug outer diameter Ø: 10 mm Cable Selection: Flexible cord without wire terminals
Power circuit: Bolt fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable selection: Flexible cord without wire terminal
Power circuit: Bolt fastening1 1…6 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cable with wire terminals
Power circuit: screw fastening2 1…4 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cable with cable terminal Power
circuit : Bolt fastening1 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 1.5…6 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Tightening torque Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz
Minimum switching voltage 17 V for signal return 17 V for signal return 17 V for signal return
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method DIN rail installation
base plate installation
DIN rail installation
base plate installation
DIN rail installation
base plate installation
environment
standard GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
high 85 mm 85 mm 85 mm
width 45 mm 45 mm 45 mm
depth 92 mm 92 mm 92 mm
Product Weight 0.37kg 0.37kg 0.37kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 5.393 cm 5.427 cm 5.427 cm
Package 1 Width 8.988 cm 8.941 cm 8.941 cm
Package 1 Length 10.057 cm 10.048 cm 10.048 cm
Package 1 Weight 410.0g 401.0g 401.0g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 Twenty one Twenty one Twenty one
Package 2 Height 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm
Package 2 Weight 9.15 kg 8.99kg 8.99kg
Unit Type of Package 3 PAL PAL PAL
Number of Units in Package 3 336 336 336
Package 3 Height 60.0cm 60.0cm 60.0cm
Package 3 Width 80.0cm 80.0cm 80.0cm
Package 3 Length 75.0cm 75.0cm 75.0cm
Package 3 Weight 146.304 kg 147.744kg 147.744kg
contract warranty
Warranty 18 months 18 months 18 months

 

Product Name LC1D25BD
Product range TeSys Deca
Product type Contactors
Short name of the product LC1D
Contactor applications It is used in AC loads with a power factor greater than or equal to 0.95,
and is used in non-inductive or slightly inductive loads and resistance furnaces
Use categories AC-4
AC-3
AC-1
AC-3e
Number of poles 3P
Rated operating voltage [UE] Power circuit: < = 690 V AC 25…400 Hz
Power circuit: < = 300 V DC
Rated operating current [IE] 25 A (at operating temperature <=60 °C) When operating voltage<=<= 440 V AC AC-3 for power circuits
: 40 A (when operating temperature <=60 °C) When operating voltage<=<= 440 V AC AC-1 for power circuits:
25 A (when operating temperature <=60 °C) When operating voltage<=<= 440 V AC AC-3e for power circuits
[Uc] control circuit voltage 24 V DC
Supplemental information
Motor power (kW) 5.5 kW at operating voltage<=220…230 V AC 50/60 Hz (AC-3)
11 kW when operating voltage<=380…400 V AC 50/60 Hz (AC-3)
11 kW when operating voltage<=415…440 V AC 50/60 Hz (AC-3).
15 kW when operating voltage<=500 V AC 50/60 Hz (AC-3)
15 kW when operating voltage<=660…690 V AC 50/60 Hz (AC-3)
5.5 kW when operating voltage<=400 V AC 50/60 Hz (AC-4)
5.5 kW when operating voltage<=220…230 V AC 50/60 Hz (AC-3e)
11 kW when operating voltage<=380…400 V AC 50/60 Hz (AC-3e)
11 kW when operating voltage<=415…440 V AC 50/60 Hz (AC-3e)
15 kW when operating voltage<=500 V AC 50/60 Hz (AC-3e).
15 kW with operating voltage <=660…690 V AC 50/60 Hz (AC-3e)
Motor power 3 hp when operating voltage<=230/240 V AC 50/60 Hz for 1-phase motors2
hp when operating voltage<=115 V AC 50/60 Hz for 1-phase motors
7.5 hp when operating voltage<=230/240 V AC 50/60 Hz for 3-phase motors
15 hp when operating voltage<=460/480 V AC 50/60 Hz for 3-phase motors
, 20 hp when operating voltage<=575/600 V AC 50/60 Hz for 3-phase motors
, 7.5 hp when operating voltage<=200/208 V AC 50/60 Hz for 3-phase motors
Model LC1D
Type of loop contact 3 NO
Protective cover bring
Conventional heating current [Ith] 10 A (when operating temperature <=60 °C) for signal circuits
, 40 A (when operating temperature <=60 °C) for power circuits
Rated Continuity Capability [IRMS] 140 A AC for signal circuits acc. to IEC 60947-5-1
250 A DC for signal circuits to IEC 60947-5-1
450 A with operating voltage <=440 V for power circuits in accordance with IEC 60947
Rated breaking capacity 450 A when operating voltage<=440 V For power supply circuits, IEC 60947 is complied with
Rated short-time withstand current [ICW] 240 A at operating temperature<=40 °C for 10 s for power circuits380
A for power circuits<=40 °C for 1 s For power circuits
: 50 A When operating temperature<=40 °C for 10 minutes For power circuits
: 120 A When operating temperature<=40 °C for 1 minute For power circuits
100 A lasts 1 s for signal loops
, 120 A for signal loops, 500 ms for signal loops,
140 A for signal loops, 100 ms for signal loops
Fuses used in conjunction with relays 10 A gG, for signal circuits according to IEC 60947-5-1
63 A gG when operating voltage <=<= 690 V with type 1, for power circuits
40 A gG when operating voltage <=<= 690 V with type 2, for power circuits
Average impedance 2 mΩ – Ith 40 A 50 Hz for power circuits
Power consumption per pole 3.2 W AC-1
1.25 W AC-3
1.25 W AC-3e
Rated insulation voltage [UI] Power Circuit: 690 V According to IEC 60947-4-1
Power Circuit: 600 V CSA Certified
Power Circuit: 600 V UL Listed
Signal Circuit: 690 V IEC 60947-1
Signal Circuit: 600 V CSA Approved
Signal Circuit: 600 V UL listed
Overvoltage category III
Pollution level 3
Rated impulse withstand voltage [UIMP] 6 kV according to IEC 60947
Safety and reliability level B10d = 1369863 times Nominal load contactors according to EN/ISO 13849-1
B10d = 20000000 times Mechanically loaded contactors according to EN/ISO 13849-1
Mechanical life 30 Mcycles
Electrical life 1.65 mcycles at 25 A AC-3 UE < = 440 V
1.4 Mcycles at 40 A AC-1 UE < = 440 V
1.65 Mcycles 25 A AC-3e UE < = 440 V
Control loop characteristics DC Standards
Surge suppression module Built-in bidirectional peak-limited diode
Control voltage limits 0.1…0.25 Uc (-40… 70 °C): coil releases DC
0.7…1.25 Uc (-40… 60 °C): coil starting DC
1…1.25 Uc (60… 70 °C): Coil start DC
Surge Power (W) 5.4 W 20 °C)
Hold-up Power Consumption (W) 5.4 W in… on 20°C
Action time 63 ± 15 % ms closed
20 ± 20 % ms breaking
Time constant 28 ms
Maximum frequency of operation 3600 times/hour at 60 °C
Wiring capacity Control loop: Bolt fastening 1 1… 4 mm² Cable type: Flexible without terminal block
Control loop: Bolt fastening 2 1… 4 mm² Cable type: Flexible without terminal control
loop: Bolt fastening 1 1… 4 mm² Cable type: Flexible wire with terminal block
Control loop: Bolt fastening 2 1… 2.5 mm² Cable type: Flexible with terminal block
Control loop: Bolt fastening 1 1… 4 mm² Cable type: Hard-wired without terminal block
Control loop: Bolt fastening 2 1… 4 mm² Cable type: Hard-wired without terminal block
Power circuit: Bolt fastening 1 2.5… 10 mm² Cable type: Flexible without terminal block
Power circuit: Bolt fastening 2 2.5… 10 mm² Cable type: Flexible without terminal block
Power circuit: Bolt fastening 1 1… 10 mm² Cable type: Flexible wire with terminal block
Power circuit: Bolt fastening 2 1.5… 6 mm² Cable type: Flexible wire with terminal block
Power circuit: Bolt fastening 1 1.5… 10 mm² Cable type: Hard-wired Without terminal block
Power circuit: Bolt fastening 2 2.5… 10 mm² Cable type: Hardwired without terminal block
Tightening torque Control loop: 1.7 N.m via bolt fastening with a screwdriver Ø 6 Flat control
loop: 1.7 N.m via bolt fastening with a screwdriver No 2 Phillips screw
power circuit: 2.5 N.m via bolt fastening with a screwdriver Ø 6 Flat power
circuit: 2.5 N.m by bolt fastening with a screwdriver No 2 Phillips screw
Control loop: 1.7 N.m via bolt fastening with a screwdriver pozidriv No 2
Power circuit: 2.5 N.m bolt fastening with a screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC according to IEC 60947-5-1
Type Mirrored with main contact status 1 NC according to IEC 60947-4-1
Signal loop frequency 25…400 Hz
Minimum switching voltage 17 V for signal loops
Minimum switching current [Imin] 5 mA for signal loops
Insulation resistance > 10 MΩ for signal loops
Do not overlap time 1.5 ms power loss between
NC and NO contacts, 1.5 ms power between NC and NO contacts
Installation: Base plate mounting
rail mounting
environment
standard CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
DIN 3852-Y
Product Certification UL
CCC
, CSA
Maritime
, UKCA
EAC,
CB Scheme
IP protection rating IP20 front panel in accordance with IEC 60529
Protective measures TH complies with IEC 60068-2-30
Climate tolerance Meets IACS E10 Exposure to hot flashes
Meets IEC 60947-1 Annex Q category D Exposure to hot flashes
Ambient air temperature -40… 60 °C
60… There is a degradation at 70 °C
Working altitude 0…3000 m
Fire resistance and abnormally high temperature resistance 850 °C according to IEC 60695-2-1
Flame retardant V1 complies with UL 94
Shock-resistant and vibration-resistant performance Seismic performance When the contact is open (2 gn (5…300 Hz))
Seismic performance When the contact is closed (4 gn (5…300 Hz))
Shock resistance When the contact is closed (15 gn (11ms))
Shock resistance When the contact is open (8 gn (11ms))
height 85 mm
width 45 mm
depth 101 mm
net weight 0.53 kg
Packing Units
Package 1: Packing unit type PCE
Package 1: Packing unit quantity 1
Package 1: Height 5.000 cm
Package 1: Width 9.300 cm
Package 1: Length 11.300 cm
Package 1: Gross weight 586.000 g
Package 2: Packing unit type S02
Package 2: Packing unit quantity 15
Package 2: Height 15.000 cm
Package 2: Width 30.000 cm
Package 2: Length 40.000 cm
Package 2: Gross weight 9.034 kg
Package 3: Packing unit type P06
Package 3: Packing unit quantity 240
Package 3: Height 75.000 cm
Package 3: Width 60.000 cm
Package 3: Length 80.000 cm
Package 3: Gross weight 152.000 kg
Contract Warranty
Warranty 18 months

 

Additional information

Weight N/A
Dimensions N/A